mirror of
https://github.com/ceph/ceph-csi.git
synced 2024-12-23 13:30:23 +00:00
196 lines
5.0 KiB
Go
196 lines
5.0 KiB
Go
|
package e2e
|
||
|
|
||
|
import (
|
||
|
"context"
|
||
|
"os"
|
||
|
|
||
|
. "github.com/onsi/ginkgo" // nolint
|
||
|
v1 "k8s.io/api/core/v1"
|
||
|
"k8s.io/apimachinery/pkg/api/resource"
|
||
|
metav1 "k8s.io/apimachinery/pkg/apis/meta/v1"
|
||
|
clientset "k8s.io/client-go/kubernetes"
|
||
|
"k8s.io/kubernetes/test/e2e/framework"
|
||
|
e2elog "k8s.io/kubernetes/test/e2e/framework/log"
|
||
|
)
|
||
|
|
||
|
var _ = Describe("RBD Upgrade Testing", func() {
|
||
|
f := framework.NewDefaultFramework("upgrade-test-rbd")
|
||
|
var (
|
||
|
// cwd stores the initial working directory.
|
||
|
cwd string
|
||
|
c clientset.Interface
|
||
|
pvc *v1.PersistentVolumeClaim
|
||
|
app *v1.Pod
|
||
|
)
|
||
|
|
||
|
// deploy rbd CSI
|
||
|
BeforeEach(func() {
|
||
|
if !upgradeTesting || !testRBD {
|
||
|
Skip("Skipping RBD Upgrade Testing")
|
||
|
}
|
||
|
c = f.ClientSet
|
||
|
if cephCSINamespace != defaultNs {
|
||
|
err := createNamespace(c, cephCSINamespace)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
}
|
||
|
createNodeLabel(f, nodeRegionLabel, regionValue)
|
||
|
createNodeLabel(f, nodeZoneLabel, zoneValue)
|
||
|
|
||
|
// fetch current working directory to switch back
|
||
|
// when we are done upgrading.
|
||
|
var err error
|
||
|
cwd, err = os.Getwd()
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
|
||
|
deployVault(f.ClientSet, deployTimeout)
|
||
|
err = upgradeAndDeployCSI(upgradeVersion, "rbd")
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
createConfigMap(rbdDirPath, f.ClientSet, f)
|
||
|
createRBDStorageClass(f.ClientSet, f, nil, nil)
|
||
|
createRBDSecret(f.ClientSet, f)
|
||
|
})
|
||
|
AfterEach(func() {
|
||
|
if !testRBD || !upgradeTesting {
|
||
|
Skip("Skipping RBD Upgrade Testing")
|
||
|
}
|
||
|
if CurrentGinkgoTestDescription().Failed {
|
||
|
// log pods created by helm chart
|
||
|
logsCSIPods("app=ceph-csi-rbd", c)
|
||
|
// log provisoner
|
||
|
logsCSIPods("app=csi-rbdplugin-provisioner", c)
|
||
|
// log node plugin
|
||
|
logsCSIPods("app=csi-rbdplugin", c)
|
||
|
}
|
||
|
|
||
|
deleteConfigMap(rbdDirPath)
|
||
|
deleteResource(rbdExamplePath + "secret.yaml")
|
||
|
deleteResource(rbdExamplePath + "storageclass.yaml")
|
||
|
deleteVault()
|
||
|
if deployRBD {
|
||
|
deleteRBDPlugin()
|
||
|
if cephCSINamespace != defaultNs {
|
||
|
err := deleteNamespace(c, cephCSINamespace)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
deleteNodeLabel(c, nodeRegionLabel)
|
||
|
deleteNodeLabel(c, nodeZoneLabel)
|
||
|
})
|
||
|
|
||
|
Context("Test RBD CSI", func() {
|
||
|
It("Test RBD CSI", func() {
|
||
|
pvcPath := rbdExamplePath + "pvc.yaml"
|
||
|
appPath := rbdExamplePath + "pod.yaml"
|
||
|
|
||
|
By("checking provisioner deployment is running", func() {
|
||
|
err := waitForDeploymentComplete(rbdDeploymentName, cephCSINamespace, f.ClientSet, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
})
|
||
|
|
||
|
By("checking nodeplugin deamonsets is running", func() {
|
||
|
err := waitForDaemonSets(rbdDaemonsetName, cephCSINamespace, f.ClientSet, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
})
|
||
|
|
||
|
By("upgrade to latest changes and verify app re-mount", func() {
|
||
|
// TODO: fetch pvc size from spec.
|
||
|
pvcSize := "2Gi"
|
||
|
var err error
|
||
|
pvc, err = loadPVC(pvcPath)
|
||
|
if pvc == nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
pvc.Namespace = f.UniqueName
|
||
|
e2elog.Logf("The PVC template %+v", pvc)
|
||
|
|
||
|
app, err = loadApp(appPath)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
app.Namespace = f.UniqueName
|
||
|
app.Labels = map[string]string{"app": "upgrade-testing"}
|
||
|
pvc.Spec.Resources.Requests[v1.ResourceStorage] = resource.MustParse(pvcSize)
|
||
|
err = createPVCAndApp("", f, pvc, app, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
err = deletePod(app.Name, app.Namespace, f.ClientSet, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
deleteRBDPlugin()
|
||
|
|
||
|
err = os.Chdir(cwd)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
|
||
|
deployRBDPlugin()
|
||
|
// validate if the app gets bound to a pvc created by
|
||
|
// an earlier release.
|
||
|
app.Labels = map[string]string{"app": "upgrade-testing"}
|
||
|
err = createApp(f.ClientSet, app, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
})
|
||
|
|
||
|
By("Resize pvc and verify expansion", func() {
|
||
|
pvcExpandSize := "5Gi"
|
||
|
|
||
|
v, err := f.ClientSet.Discovery().ServerVersion()
|
||
|
if err != nil {
|
||
|
e2elog.Logf("failed to get server version with error %v", err)
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
// Resize 0.3.0 is only supported from v1.15+
|
||
|
if v.Major > "1" || (v.Major == "1" && v.Minor >= "15") {
|
||
|
opt := metav1.ListOptions{
|
||
|
LabelSelector: "app=upgrade-testing",
|
||
|
}
|
||
|
pvc, err = f.ClientSet.CoreV1().PersistentVolumeClaims(pvc.Namespace).Get(context.TODO(), pvc.Name, metav1.GetOptions{})
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
|
||
|
// resize PVC
|
||
|
err = expandPVCSize(f.ClientSet, pvc, pvcExpandSize, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
// wait for application pod to come up after resize
|
||
|
err = waitForPodInRunningState(app.Name, app.Namespace, f.ClientSet, deployTimeout)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
// validate if resize is successful.
|
||
|
err = checkDirSize(app, f, &opt, pvcExpandSize)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
}
|
||
|
|
||
|
})
|
||
|
|
||
|
By("delete pvc and app", func() {
|
||
|
err := deletePVCAndApp("", f, pvc, app)
|
||
|
if err != nil {
|
||
|
Fail(err.Error())
|
||
|
}
|
||
|
})
|
||
|
})
|
||
|
})
|
||
|
})
|