1
0
mirror of https://github.com/ceph/ceph-csi.git synced 2024-12-21 04:20:23 +00:00
Commit Graph

25 Commits

Author SHA1 Message Date
Prasanna Kumar Kalever
29a3f4acf6 cleanup: ReconcilePersistentVolume consider passing it by pointer
Address: hugeParam linter

internal/controller/persistentvolume/persistentvolume.go:59:7:
hugeParam: r is heavy (80 bytes); consider passing it by pointer
(gocritic)
[...]
internal/controller/persistentvolume/persistentvolume.go:135:7:
hugeParam: r is heavy (80 bytes); consider passing it by pointer
(gocritic)
func (r ReconcilePersistentVolume) reconcilePV(ctx context.Context, obj
runtime.Object) error {}

Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
2022-06-28 19:12:53 +00:00
Prasanna Kumar Kalever
caf4090657 rbd: provide option to disable setting metadata on rbd images
As we added support to set the metadata on the rbd images created for
the PVC and volume snapshot, by default metadata is set on all the images.

As we have seen we are hitting issues#2327 a lot of times with this,
we start to leave a lot of stale images. Currently, we rely on
`--extra-create-metadata=true` to decide to set the metadata or not,
we cannot set this option to false to disable setting metadata because we
use this for encryption too.

This changes is to provide an option to disable setting the image
metadata when starting cephcsi.

Fixes: 
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
2022-06-28 19:12:53 +00:00
Prasanna Kumar Kalever
2880c25fd6 rbd: set cluster Name as metadata on the image
This change helps read the cluster name from the cmdline args,
the provisioner will set the same on the RBD images.

Fixes: 
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
2022-06-08 16:23:59 +00:00
Madhu Rajanna
1952a9b4b3 ci: fix all linter errors found in golangci-lint
Fixing all the linter errors found in golang-ci
lint v1.46.2

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2022-06-03 12:55:54 +00:00
Madhu Rajanna
d886ab0d66 rbd: use leases for leader election
use leases for leader election instead
of the deprecated configmap based leader
election.

This PR is making leases as default leader election
refer https://github.com/kubernetes-sigs/
controller-runtime/pull/1773, default from configmap
to configmap leases was done with
https://github.com/kubernetes-sigs/
controller-runtime/pull/1144.

Release notes https://github.com/kubernetes-sigs/
controller-runtime/releases/tag/v0.7.0

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2022-04-14 06:46:50 +00:00
Prasanna Kumar Kalever
ae5925f04c rbd: update PV/PVC metadata on a reattach of PV
Example if a PVC was delete by setting `persistentVolumeReclaimPolicy` as
`Retain` on PV, and PV is reattached to a new PVC, we make sure to update
PV/PVC image metadata on a PV reattach.

Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
2022-04-08 15:43:14 +00:00
Madhu Rajanna
8c5e414d53 rbd: do not read pvc namespace from volume attributes
Below are the 3 different cases where we need
the PVC namespace for encryption

* CreateVolume:- Read the namespace from the
createVolume parameters and store it in the omap
* NodeStage:- Read the namespace from the omap
not from the volumeContext
* Regenerate:- Read the pvc namespace from the claimRef
not from the volumeAttributes.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2022-03-21 08:54:43 +00:00
Madhu Rajanna
50d6ea825c rbd: remove retrieving volumeHandle from PV annotation
we have added clusterID mapping to identify the volumes
in case of a failover in Disaster recovery in .
with  we are moving to a configuration in
configmap for clusterID and poolID mapping.
and with  we have all the required information
to identify the image mappings.
This commit removes the workaround implementation done
in .

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2021-12-17 03:38:29 +00:00
Humble Chirammal
4efcc5bf97 cleanup: simplify checkStaticVolume function and remove unwanted vars
checkStaticVolume() in the reconcilePV function has been unwantedly
introducing variables to confirm the pv spec is static or not. This
patch simplify it and make a smaller footprint of the functions.

Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
2021-09-07 12:51:30 +00:00
Niels de Vos
6d00b39886 cleanup: move log functions to new internal/util/log package
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.

Updates: 
Signed-off-by: Niels de Vos <ndevos@redhat.com>
2021-08-26 09:34:05 +00:00
Humble Chirammal
9ac1391d0f util: correct interface name and remove redundancy
ContollerManager had a typo in it, and if we correct it,
linter  will fail and suggest not to use controller.ControllerManager
as the interface name and package name  is redundant, keeping manager
as the interface name which is the practice and also address the
linter issues.

Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
2021-08-19 04:19:42 +00:00
Rakshith R
b9b4b1e34e rbd: refractor RegenerateJournal() to take in volumeAttributes
This commit refractors RegenerateJournal() to take in
volumeAttributes map[string]string as argument so it
can extract required attributes internally.

Signed-off-by: Rakshith R <rar@redhat.com>
2021-08-10 09:17:59 +00:00
Rakshith R
43f753760b cleanup: resolve nlreturn linter issues
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.

Updates: 

Signed-off-by: Rakshith R <rar@redhat.com>
2021-07-22 06:05:01 +00:00
Yati Padia
f36d611ef9 cleanup: resolves gofumpt issues of internal codes
This PR runs gofumpt for internal folder.

Updates: 

Signed-off-by: Yati Padia <ypadia@redhat.com>
2021-07-14 19:50:56 +00:00
Rakshith R
9eaa55506f rebase: update controller-runtime package to v0.9.2
This commit updates controller-runtime to v0.9.2 and
makes changes in persistentvolume.go to add context to
various functions and function calls made here instead of
context.TODO().

Signed-off-by: Rakshith R <rar@redhat.com>
2021-07-01 03:35:23 +00:00
Humble Chirammal
f526c4a5e8 internal: reformat long lines in internal/controller package to 120 chars
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in 'internal/controller' package to restrict the line length to 120 chars.

Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
2021-06-28 14:43:49 +00:00
Yati Padia
847b996501 cleanup: Modifies Wrapcheck linter
Wrapcheck is a  simple Go linter to check that errors
from external packages are wrapped during return to
help identify the error source during debugging.
This commit addresses the wrapcheck error

Updates:#2025

Signed-off-by: Yati Padia <ypadia@redhat.com>
2021-06-22 08:47:55 +00:00
Humble Chirammal
0fae0e53b6 cleanup: various source code comment corrections
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
2021-04-16 10:22:35 +00:00
Madhu Rajanna
e2fa84357a rbd: take lock when reconciling the PV
there can be a change we can reconcile same
PV parallelly we can endup in generating and
deleting multiple omap keys. to be on safer
side taking lock to process one volumeHandle
at a time.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2021-04-07 11:46:27 +00:00
Madhu Rajanna
0f8813d89f rbd:store/Read volumeID in/from PV annotation
In the case of the Async DR, the volumeID will
not be the same if the clusterID or the PoolID
is different, With Earlier implementation, it
is expected that the new volumeID mapping is
stored in the rados omap pool. In the case of the
ControllerExpand or the DeleteVolume Request,
the only volumeID will be sent it's not possible
to find the corresponding poolID in the new cluster.

With This Change, it works as below

The csi-rbdplugin-controller will watch for the PV
objects, when there are any PV objects created it
will check the omap already exists, If the omap doesn't
exist it will generate the new volumeID and it checks for
the volumeID mapping entry in the PV annotation, if the
mapping does not exist, it will add the new entry
to the PV annotation.

The cephcsi will check for the PV annotations if the
omap does not exist if the mapping exists in the PV
annotation, it will use the new volumeID for further
operations.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2021-04-07 11:46:27 +00:00
Rakshith R
0f7b653b4e cleanup: refactor deeply nested if statements in persistentvolume.go
Refactored deeply nested if statement in persistentvolume.go to
reduce cognitive complexity.

Signed-off-by: Rakshith R <rar@redhat.com>
2021-04-07 02:31:41 +00:00
Niels de Vos
37471c7a5f cleanup: return error type in ReconcilePersistentVolume.getCredentials()
Signed-off-by: Niels de Vos <ndevos@redhat.com>
2020-12-09 08:35:35 +00:00
Madhu Rajanna
b2fb43b335 cleanup: reduce the code complexity of controller
created a new helper function to getCredentials.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2020-12-07 11:03:27 +00:00
Madhu Rajanna
e243c0006b rbd: dont generate OMAP data for static volume
if the user has created a static PV for a RBD
image which is not created by CSI driver, dont
generate the OMAP data.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2020-12-07 11:03:27 +00:00
Madhu Rajanna
68bd44beba rbd: add new controller to regenerate omap data
In the case of Disaster Recovery failover, the
user expected to create the static PVC's. We have
planned not to go with the PVC name and namespace
for many reasons (as in kubernetes it's planned to
support PVC transfer to a new namespace with a
different name and with new features coming in
like data populator etc). For now, we are
planning to go with static PVC's to support
async mirroring.

During Async mirroring only the RBD images are
mirrored to the secondary site, and when the
user creates the static PVC's on the failover
we need to regenerate the omap data. The
volumeHandler in PV spec is an encoded string
which contains clusterID and poolID and image UUID,
The clusterID and poolID won't remain same on both
the clusters, for that cephcsi need to generate the
new volume handler and its to create a mapping
between new volume handler and old volume handler
with that whenever cephcsi gets csi requests it
check if the mapping exists it will pull the new
volume handler and continues other operations.

The new controller watches for the PVs created,
It checks if the omap exists if it doesn't it
will regenerate the entire omap data.

Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
2020-11-28 18:50:00 +00:00