we have added clusterID mapping to identify the volumes
in case of a failover in Disaster recovery in #1946.
with #2314 we are moving to a configuration in
configmap for clusterID and poolID mapping.
and with #2314 we have all the required information
to identify the image mappings.
This commit removes the workaround implementation done
in #1946.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
HexStringToInteger() used to return a uint64, but everywhere else uint
is used. Having HexStringToInteger() return a uint as well makes it a
little easier to use when setting it with SetGlobalInt().
Signed-off-by: Niels de Vos <ndevos@redhat.com>
When the rbd-driver starts, it initializes some global (yuck!) variables
in the rbd package. Because the rbd-driver is moved out into its own
package, these variables can not easily be set anymore.
Introcude SetGlobalInt(), SetGlobalBool() and InitJournals() so that the
rbd-driver can configure the rbd package.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
genVolFromVolID() is used by the CSI Controller service to create an
rbdVolume object from a CSI volume_id. This function is useful for
CSI-Addons Services as well, so rename it to GenVolFromVolID().
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Moved to add scheduling to the promote
operation as scheduling need to be added
when the image is promoted and this is
the correct method of adding the scheduling
to make the scheduling take place.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Currently, we recognize and warn for the provided image features based on
our prior intelligence at ceph-csi (i.e based on supportedFeatures map
and validateImageFeatures) at image/PV creation time. It might be very
much possible that the cluster is heterogeneous i.e. the PV creation and
application container might both be on different nodes with different
kernel versions (krbd driver versions).
This PR adds a mechanism to check for the supported krbd features during
mount time, if the krbd driver doesn't have the specified image feature
then it will fall back to rbd-nbd mounter.
Fixes: #478
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
After moving moving image to trash, if `trash remove` step fails,
then external-provisioner will issue subsequent requests, in which
image will be absent in pool( will be in trash) and omap cleanup will
be done with stale image left in trash with no `trash remove` step on it.
To avoid this scenario list trash images and find corresponding id for given
image name and add a task to flatten when we encounter a ErrImageNotFound.
Fixes: #1728
Signed-off-by: Rakshith R <rar@redhat.com>
During PVC snapshot/clone both kms config and passphrase needs to copied,
while for PVC restore only passphrase needs to be copied to dest rbdvol
since destination storageclass may have another kms config.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit adds the logic to detect a passed in volumeID
is a migrated volume ID and if yes, the driver connect to the
backend cluster and clean/delete the image. The logic
only applied if its a migration volume ID. The migration volume ID
carry the information like mons, pool and image name which is
good enough for the driver to identify and connect to the backend
cluster for its operations.
migration volID format:
<mig>_mons-<monsHash>_image-<imageUID>_<poolHash>
Details on the hash values:
* MonsHash: this carry a hash value (md5sum) which will be acted as the
`clusterID` for the operations in this context.
* ImageUID: this is the unique UUID generated by kubernetes for the created
volume.
* PoolHash: this is an encoded string of pool name.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
as we are refractoring the cephfs code,
Moving all the core functions to a new folder
/pkg called core. This will make things easier
to implement. For now onwards all the core
functionalities will be added to the core
package.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
the migration nodestage request does not carry the 'clusterID' in it
and only monitors are available with the volumeContext. The volume
context flag 'migration=true' and 'static=true' flags allow us to
fill 'clusterID' from the passed in monitors to the volume Context,so
that rest of the static operations on nodestage can be proceeded as we
do treat static volumes today.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Currently, we delete the ceph client log file on unmap/detach.
This patch provides additional alternatives for users who would like to
persist the log files.
Strategies:
-----------
`remove`: delete log file on unmap/detach
`compress`: compress the log file to gzip on unmap/detach
`preserve`: preserve the log file in text format
Note that the default strategy will be remove on unmap, and these options
can be tweaked from the storage class
Compression size details example:
On Map: (with debug-rbd=20)
---------
$ ls -lh
-rw-r--r-- 1 root root 526K Sep 1 18:15
rbd-nbd-0001-0024-fed5480a-f00f-417a-a51d-31d8a8144c03-0000000000000003-d2e89c87-0b4d-11ec-8ea6-160f128e682d.log
On unmap:
---------
$ ls -lh
-rw-r--r-- 1 root root 33K Sep 1 18:15
rbd-nbd-0001-0024-fed5480a-f00f-417a-a51d-31d8a8144c03-0000000000000003-d2e89c87-0b4d-11ec-8ea6-160f128e682d.gz
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
This commit:
- modifies GetMonsAndClusterID() to take clusterID instead of options.
- moves out validation of clusterID is set or not out of GetMonsAndClusterID().
- defines ErrClusterIDNotSet new error for reusability.
- add GetClusterID() to obtain clusterID from options.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit adds capability to genVolFromVolumeOptions() to fetch
mapped clusted-id & mon ips for mirrored PVC on secondary cluster
which may have different cluster-id.
This is required for NodeStageVolume().
We also don't need to check for mapping during volume create requests,
so it can be disabled by passing a bool checkClusterIDMapping as false.
GetMonsAndClusterID() is modified to accept bool checkClusterIDMapping
based on which clustermapping is checked to fetch mapped cluster-id and
mon-ips.
Signed-off-by: Rakshith R <rar@redhat.com>
Thanks to the random unmap failure on my local machine:
I0901 17:08:37.841890 2617035 cephcmds.go:55] ID: 11 Req-ID:
0001-0024-fed5480a-f00f-417a-a51d-31d8a8144c03-0000000000000003-024983f3-0b47-11ec-8fcb-e671f0b9f58e
an error (exit status 22) occurred while running rbd args: [unmap
rbd-pool/csi-vol-024983f3-0b47-11ec-8fcb-e671f0b9f58e --device-type nbd
--options try-netlink --options reattach-timeout=300 --options
io-timeout=0]
Noticed the map args are also getting passed to/as unmap args, which is not
correct. We have separate things for mapOptions and unmapOptions. This PR
makes sure that the map args are not passed at the time of unmap.
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
When NewK8sClient() detects and error, it used to call FatalLogMsg()
which causes a panic. There are additional features that can be used on
Kubernetes clusters, but these are not a requirement for most
functionalities of the driver.
Instead of causing a panic, returning an error should suffice. This
allows using the driver on non-Kubernetes clusters again.
Fixes: #2452
Signed-off-by: Niels de Vos <ndevos@redhat.com>
This commit moves getMappedID() from rbd to util
package since it is not rbd specific and exports
it from there.
Signed-off-by: Rakshith R <rar@redhat.com>
By placing the NewK8sClient() function in its own package, the KMS API
can be split from the "internal/util" package. Some of the KMS providers
use the NewK8sClient() function, and this causes circular dependencies
between "internal/utils" -> "internal/kms" -> "internal/utils", which
are not alowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
- Update the meta stash with logDir details
- Use the same to remove logfile on unstage/unmap to be space efficient
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
- One logfile per device/volume
- Add ability to customize the logdir, default: /var/log/ceph
Note: if user customizes the hostpath to something else other than default
/var/log/ceph, then it is his responsibility to update the `cephLogDir`
in storageclass to reflect the same with daemon:
```
cephLogDir: "/var/log/mynewpath"
```
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
Whenever Ceph-CSI receives a CSI/Replication
request it will first decode the
volumeHandle and try to get the required
OMAP details if it is not able to
retrieve, receives a `Not Found` error
message and Ceph-CSI will check for the
clusterID mapping. If the old volumeID
`0001-00013-site1-storage-0000000000000001
-b0285c97-a0ce-11eb-8c66-0242ac110002`
contains the `site1-storage` as the clusterID,
now Ceph-CSI will look for the corresponding
clusterID `site2-storage` from the above configmap.
If the clusterID mapping is found now Ceph-CSI
will look for the poolID mapping ie mapping between
`1` and `2`. Example:- pool with name exists on
both the clusters with different ID's Replicapool
with ID `1` on site1 and Replicapool with ID `2`
on site2. After getting the required mapping Ceph-CSI
has the required information to get more details
from the rados OMAP. If we have multiple clusterID mapping
it will loop through all the mapping and checks the
corresponding pool to get the OMAP data. If the clusterID
mapping does not exist Ceph-CSI will return an `Not Found`
error message to the caller.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Currently we have a bug that we are not using rados
namespace when adding ceph manager command to
remove the image from the trash. This commit
adds the missing rados namespace when adding
ceph manager task.
without fix the image will be moved to trash
and no task will be added to remove from the
trash. it will become ceph responsibility to
remove the image from trash when it will cleanup
the trash.
workaroud: manually purge the trash
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The new MigrateMetadata() function can be used to get the metadata of an
image with a deprecated and new key. Renaming metadata keys can be done
easily this way.
A default value will be set in the image metadata when it is missing
completely. But if the deprecated key was set, the data is stored under
the new key and the deprecated key is removed.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
This commit resolves errorlint issues
which checks for the code that will cause
problems with the error wrapping scheme.
Updates: #1586
Signed-off-by: Yati Padia <ypadia@redhat.com>
As part of stage transaction if the mounter is of type nbd, then capture
device path after a successful rbd-nbd map.
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
setting metadata in isThickProvisioned method
helps us to avoid checking thick metakey and
deprecated metakey for both thick and thin
provisioned images and also this will easily
help us to migrated the deprecated key to new key.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
isThickProvisioned is already method of the rbdImage
to keep similar thick provisioner related functions
common making isThickProvisioned as method of rbdImage.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
As image metadata key starting with '.rbd' will not
be copied when we do clone or mirroring, deprecating
the old key for the same reason use
'csi.ceph.com/thick-provisioned' to set image metadata.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Mirror-snapshots can also be automatically created on a
periodic basis if mirror-snapshot schedules are defined.
The mirror-snapshot can be scheduled globally, per-pool,
or per-image levels. Multiple mirror-snapshot schedules
can be defined at any level.
To create a mirror-snapshot schedule with rbd, specify
the mirror snapshot schedule add command along with an
optional pool or image name; interval; and optional start time:
The interval can be specified in days, hours, or minutes
using d, h, m suffix respectively. The optional start-time
can be specified using the ISO 8601 time format. For example:
```
$ rbd --cluster site-a mirror snapshot schedule
add --pool image-pool --image image1 24h 14:00:00-05:00
```
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in below files, and restrict the line length to 120 chars.
-internal/rbd/rbd_attach.go
-internal/rbd/rbd_journal.go
-internal/rbd/rbd_util.go
-internal/rbd/replicationcontrollerserver.go
-internal/rbd/snapshot.go
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Added helper func isNotMountPoint to check mountPoint,
validate error and reduce complexity of NodeStageVolume.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit adds checks for missing `imageFeatures` parameter
in createvolumerequest and nodestagerequest(only for static PVs).
Missing `imageFeatures` parameter is ignored in case of non-static
PVs to ensure backwards compatibility with older versions which
did not have `imageFeatures` as required parameter.
Signed-off-by: Rakshith R <rar@redhat.com>
RbdSnapName holds the actual RBD image name which
got created during the CreateSnapshot operation.
RbdImageName holds the name of the parent from
which the snapshot is created. and the parent
is independent of snapshot and it can be deleted
any time for the same reason using the RbdSnapName
to check the rbd image details.
generate a temporary volume from the snapshot which
replaces the rbdImageName with RbdSnapName and use
it to check the image metadata.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
added validation to allow only Restore of Thick PVC
snapshot to a thick clone and creation of thick clone
from thick PVC.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
isThickProvisioned can be used for both snapshot
and clone validation if isThickProvisioned is method
of common rbdImage structure.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Not all Linux kernels support the deep-flatten feature. Disabling the
feature makes it possible to map RBD images on older kernels (like what
minikube uses).
Signed-off-by: Niels de Vos <ndevos@redhat.com>
To create a full-allocated RBD image from a snapshot/clone DeepCopy()
can be used. This is needed when the parent of the new volume is
thick-provisioner, so that the new volume is independent of the parent
and thick-provisioned as well.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
isCompatibleEncryption is used to validate the
requested volume and the existing volume and
the destination volume name wont be generated yet
and logging the destination volume prints the empty
image name with pool name.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
actual error will be present in the stdErr not the error
when we try to add a task to flatten the rbd image. This
commits corrects the error checking when the image does
not have a parent.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
While traversing image chain, the parent
image can be present in a different pool
that the one child is in. So, updating
pool name in the next itteration to
that of the Parent.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
if the parent and child clones are in
different namespaces we need to open a new
ioctx for pools.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>