This commit adds nfs nodeserver capable of
mounting nfs volumes, even with pod networking
using NSenter design similar to rbd and cephfs.
NodePublish, NodeUnpublish, NodeGetVolumeStats
and NodeGetCapabilities have been implemented.
The nodeserver implementation has been inspired
from https://github.com/kubernetes-csi/csi-driver-nfs,
which was previously used for mounted cephcsi exported
nfs volumes. The current implementation is also
backward compatible for the previously created
PVCs.
Signed-off-by: Rakshith R <rar@redhat.com>
Recently the k8s.io/mount-utils package added more runtime dectection.
When creating a new Mounter, the detect is run every time. This is
unfortunate, as it logs a message like the following:
```
mount_linux.go:283] Detected umount with safe 'not mounted' behavior
```
This message might be useful, so it probably good to keep it.
In Ceph-CSI there are various locations where Mounter instances are
created. Moving that to the DefaultNodeServer type reduces it to a
single place. Some utility functions need to accept the additional
parameter too, so that has been modified as well.
See-also: kubernetes/kubernetes#109676
Signed-off-by: Niels de Vos <ndevos@redhat.com>
These RPCs( nodestage,unstage,volumestats) are
implemented RPCs for our drivers atm. This commit removes
the `unimplemented` responses from the common/default
server initialization routins.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in 'internal/csi-common' package to restrict the line length to 120 chars.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
The CephFS NodeServer should handle the CephFS specific requests. This
is not something that the NodeServer for RBD should handle.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
if the PVC access mode is ReadOnlyMany
or single node readonly, mounting the rbd
device path to the staging path as readonly
to avoid the write operation.
If the PVC acccess mode is readonly, mapping
rbd images as readonly.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The internal/ directory in Go has a special meaning, and indicates that
those packages are not meant for external consumption. Ceph-CSI does
provide public APIs for other projects to consume. There is no plan to
keep the API of the internally used packages stable.
Closes: #903
Signed-off-by: Niels de Vos <ndevos@redhat.com>