in case of mirrored image, if the image is
primary a watcher will be added by the rbd
mirror deamon on the rbd image.
we have to consider 2 watcher to check image
is in use.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
incase of async mirroring the volume UUID is
retrieved from the volume name, instead of cephcsi
generating a new UUID it should reserve the passed
UUID it will be useful when we support both metro DR
and async mirroring on a kubernetes clusters.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
An rbd image can have a maximum number of
snapshots defined by maxsnapshotsonimage
On the limit is reached the cephcsi will
start flattening the older snapshots and
returns the ABORT error message, The Request
comes after this as to wait till all the
images are flattened (this will increase the
PVC creation time. Instead of waiting till
the maximum snapshots on an RBD image, we can
have a soft limit, once the limit reached
cephcsi will start flattening the task to
break the chain. With this PVC creation time
will only be affected when the hard limit
(minsnapshotsonimage) reached.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The function isCloneRetryError verifies
if the clone error is `pending` or
`in-progress` error.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
In certain cases, clone status can be 'pending'.
In that case, abort error message should be
returned similar to that during 'in-progress'
state.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
There is a type-check on BytesQuota after calling SubVolumeInfo() to see
if the value is supported. In case no quota is configured, the value
Infinite is returned. This can not be converted to an int64, so the
original code returned an error.
It seems that attaching/mounting sometimes fails with the following
error:
FailedMount: MountVolume.MountDevice failed for volume "pvc-0e8fdd18-873b-4420-bd27-fa6c02a49496" : rpc error: code = Internal desc = subvolume csi-vol-0d68d71a-1f5f-11eb-96d2-0242ac110012 has unsupported quota: infinite
By ignoring the quota of Infinite, and not setting a quota in the
Subvolume object, this problem should not happen again.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The implementation of getOMapValues assumed that the number of key-value
pairs assigned to the object would be close to the number of keys
being requested. When the number of keys on the object exceeded the
"listExcess" value the function would fail to read additional keys
even if they existed in the omap.
This change sets a large fixed "chunk size" value and keeps reading
key-value pairs as long as the callback gets called and increments
the numKeys counter.
Signed-off-by: John Mulligan <jmulligan@redhat.com>
When using go-ceph and the volumeOptions.Connect() call, the credentials
are not needed once the connection is established.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Reduce the number of calls to the `ceph fs` executable to improve
performance of CephFS volume resizing.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
This prepares resizeVolume() so that the volumeOptions.conn can be used
for connecting with go-ceph and use the connection cache.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
We have below exported function in credentials.go which is not
called from anywhere in the repo. Removing it for the same reason.
```
// NewCredentials generates new credentials when id and key
// are provided.
func NewCredentials(id, key string) (*Credentials, error) {
...
```
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
`cap` builtin function returns the capacity of a type. Its not
good practice to use this builtin function for other variable
names, removing it here
Ref# https://golang.org/pkg/builtin/#cap
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
golang-ci suddenly complains about the following issue
internal/cephfs/util.go:41:1: directive `// nolint:unparam // todo:program values has to be revisited later` is unused for linter unparam (nolintlint)
// nolint:unparam // todo:program values has to be revisited later
^
Dropping the comment completely seems to fix it. Ideally
execCommandJSON() will get removed once the migration to go-ceph is
complete.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
volJournal.Connect() got the error on err2 variable, however
the return was on variable err which hold the error return of
DecomposeCSIID() which is wrong. This cause the error return wrongly
parsed and pushed from the caller. From now on, we are reusing the
err variable to hold and revert the error of volJournal.Connect().
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Previously the purgeVolume error was ignored due to wrong error variable
check in the createVolume. With this change it checks on the proper error.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
The allocated, and potentially connected, volumeOptions object in
newVolumeOptionsFromVolID() is not cleaned-up in case of errors. This
could cause resource leaks.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Without connection, follow-up oparations on the volumeOptions object
will cause a panic. This should fix a regression in CephFS testing.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
All the previous condition checks exit from the function and
when it reach to this block its obvious that error is non nil,
we dont need an extra check here.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
There is no need to pass all secrets on to newVolumeOptions(), it only
needs the credentials. As the caller of newVolumeOptions() already has
the credentials generated, just pass them along instead of the raw
secrets.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The credentials are not used anymore, the volume object is already
connected to the cluster when createVolume() is called.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The go-ceph CephFS Admin API needs a rados.Conn to connect the Admin
interface to the Ceph cluster. As the rados.Conn is internal to the
ClusterConnection type, add GetFSAdmin() to create a new FSAdmin
instance for a specific connection.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Add the ClusterConnection to the volumeOptions type, so that future use
of go-ceph can connect to the Ceph cluster.
Once a volumeOptions object is not needed anymore, it needs to get
destroyed to free associated resources like the ClusterConnection.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The error check condition in genVolFromID() is always false as far as
code reading/workflow goes. Removing it for the same reason.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
cephcsi uses cli for fetching snap list as well as to check the
snapshot namespace, replaced that with go-ceph calls.
Signed-off-by: Mudit Agarwal <muagarwa@redhat.com>
return a proper error message to the user when
the subvolume has the snapshots and it cannot
be removed until the snapshots on the subvolume
have to be deleted.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
When passing
fuseMountOptions: debug
in the StorageClass, the mount options passed on the ceph-fuse
commandline result in "-o nonempty ,debug". The additional space before
the ",debug" causes the mount command to fail.
Fixes: 1485
Signed-off-by: Niels de Vos <ndevos@redhat.com>