With the new support for passing --options, referring to ExecCommand()
argument slices as mapOptions and options is confusing.
Signed-off-by: Ilya Dryomov <idryomov@gmail.com>
(cherry picked from commit 5631b83dd0)
rbd device list --format=json returns namespace as a namespace not radosNamespace
Signed-off-by: Seena Fallah <seenafallah@gmail.com>
(cherry picked from commit fdec9f65b8)
if the user has created a static PV for a RBD
image which is not created by CSI driver, dont
generate the OMAP data.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
If cephcsi encounters any error after
reservation, as a cleanup operation
it should revert back the reservation.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
If the omap data already exits return nil.
so that omap generator will not try to reserve
anything again.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
clusterAdditionalInfo map is holding a localClusterState
for checking ceph cluster supports resize and subvolumegroup
is created or not, currently we are checking if the key is present
in a map and localClusterStatelocalClusterState.resizeSupported
is set to false to call ceph fs subvolume resize to check command is
supported or not, if a structure is initialized all its members
are set to default value. so we will never going to check the
ceph fs subvolume resize command is supported in backend or not, we are
always using ceph fs subvolume create to resize subvolume. in some
ceph version ceph fs subvolume create wont work to resize a subvolume.
This commit changes the resizeSupported from bool to *bool for
proper handling of this scenario.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
go ceph returns NotImplementedError for invalid
commands,cephcsi is using errors.As to find out
the error.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
go ceph returns NotImplementedError for invalid
commands,cephcsi is using errors.As to find out
the error.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In order to re-use the configuration of Vault, split a new
vaultConnection type from the VaultKMS type.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
getCloneInfo() does not need to return a full CloneStatus struct that
only has one member. Instead, it can just return the value of the single
member, so the JSON type/struct does not need to be exposed.
This makes the API for getCloneInfo() a little simpler, so it can be
replaced by a go-ceph implementation later on.
As the function does not return any of the unused attributes anymore, it
is renamed to getCloneStatu() as well.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Instead of the hand-rolled Vault usage, use the libopenstorage/secrets
package that provides a nice API. The support for Vault becomes much
simpler and maintainable that way.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
earlier if the depth check fails the
complete vol struct was getting logged,
this commits logs only the pool and image
name.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In the case of Disaster Recovery failover, the
user expected to create the static PVC's. We have
planned not to go with the PVC name and namespace
for many reasons (as in kubernetes it's planned to
support PVC transfer to a new namespace with a
different name and with new features coming in
like data populator etc). For now, we are
planning to go with static PVC's to support
async mirroring.
During Async mirroring only the RBD images are
mirrored to the secondary site, and when the
user creates the static PVC's on the failover
we need to regenerate the omap data. The
volumeHandler in PV spec is an encoded string
which contains clusterID and poolID and image UUID,
The clusterID and poolID won't remain same on both
the clusters, for that cephcsi need to generate the
new volume handler and its to create a mapping
between new volume handler and old volume handler
with that whenever cephcsi gets csi requests it
check if the mapping exists it will pull the new
volume handler and continues other operations.
The new controller watches for the PVs created,
It checks if the omap exists if it doesn't it
will regenerate the entire omap data.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
in case of mirrored image, if the image is
primary a watcher will be added by the rbd
mirror deamon on the rbd image.
we have to consider 2 watcher to check image
is in use.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
incase of async mirroring the volume UUID is
retrieved from the volume name, instead of cephcsi
generating a new UUID it should reserve the passed
UUID it will be useful when we support both metro DR
and async mirroring on a kubernetes clusters.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
An rbd image can have a maximum number of
snapshots defined by maxsnapshotsonimage
On the limit is reached the cephcsi will
start flattening the older snapshots and
returns the ABORT error message, The Request
comes after this as to wait till all the
images are flattened (this will increase the
PVC creation time. Instead of waiting till
the maximum snapshots on an RBD image, we can
have a soft limit, once the limit reached
cephcsi will start flattening the task to
break the chain. With this PVC creation time
will only be affected when the hard limit
(minsnapshotsonimage) reached.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The function isCloneRetryError verifies
if the clone error is `pending` or
`in-progress` error.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
In certain cases, clone status can be 'pending'.
In that case, abort error message should be
returned similar to that during 'in-progress'
state.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
There is a type-check on BytesQuota after calling SubVolumeInfo() to see
if the value is supported. In case no quota is configured, the value
Infinite is returned. This can not be converted to an int64, so the
original code returned an error.
It seems that attaching/mounting sometimes fails with the following
error:
FailedMount: MountVolume.MountDevice failed for volume "pvc-0e8fdd18-873b-4420-bd27-fa6c02a49496" : rpc error: code = Internal desc = subvolume csi-vol-0d68d71a-1f5f-11eb-96d2-0242ac110012 has unsupported quota: infinite
By ignoring the quota of Infinite, and not setting a quota in the
Subvolume object, this problem should not happen again.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The implementation of getOMapValues assumed that the number of key-value
pairs assigned to the object would be close to the number of keys
being requested. When the number of keys on the object exceeded the
"listExcess" value the function would fail to read additional keys
even if they existed in the omap.
This change sets a large fixed "chunk size" value and keeps reading
key-value pairs as long as the callback gets called and increments
the numKeys counter.
Signed-off-by: John Mulligan <jmulligan@redhat.com>