HexStringToInteger() used to return a uint64, but everywhere else uint
is used. Having HexStringToInteger() return a uint as well makes it a
little easier to use when setting it with SetGlobalInt().
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Currently, we recognize and warn for the provided image features based on
our prior intelligence at ceph-csi (i.e based on supportedFeatures map
and validateImageFeatures) at image/PV creation time. It might be very
much possible that the cluster is heterogeneous i.e. the PV creation and
application container might both be on different nodes with different
kernel versions (krbd driver versions).
This PR adds a mechanism to check for the supported krbd features during
mount time, if the krbd driver doesn't have the specified image feature
then it will fall back to rbd-nbd mounter.
Fixes: #478
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
Currently, we delete the ceph client log file on unmap/detach.
This patch provides additional alternatives for users who would like to
persist the log files.
Strategies:
-----------
`remove`: delete log file on unmap/detach
`compress`: compress the log file to gzip on unmap/detach
`preserve`: preserve the log file in text format
Note that the default strategy will be remove on unmap, and these options
can be tweaked from the storage class
Compression size details example:
On Map: (with debug-rbd=20)
---------
$ ls -lh
-rw-r--r-- 1 root root 526K Sep 1 18:15
rbd-nbd-0001-0024-fed5480a-f00f-417a-a51d-31d8a8144c03-0000000000000003-d2e89c87-0b4d-11ec-8ea6-160f128e682d.log
On unmap:
---------
$ ls -lh
-rw-r--r-- 1 root root 33K Sep 1 18:15
rbd-nbd-0001-0024-fed5480a-f00f-417a-a51d-31d8a8144c03-0000000000000003-d2e89c87-0b4d-11ec-8ea6-160f128e682d.gz
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
This commit moves getMappedID() from rbd to util
package since it is not rbd specific and exports
it from there.
Signed-off-by: Rakshith R <rar@redhat.com>
Whenever Ceph-CSI receives a CSI/Replication
request it will first decode the
volumeHandle and try to get the required
OMAP details if it is not able to
retrieve, receives a `Not Found` error
message and Ceph-CSI will check for the
clusterID mapping. If the old volumeID
`0001-00013-site1-storage-0000000000000001
-b0285c97-a0ce-11eb-8c66-0242ac110002`
contains the `site1-storage` as the clusterID,
now Ceph-CSI will look for the corresponding
clusterID `site2-storage` from the above configmap.
If the clusterID mapping is found now Ceph-CSI
will look for the poolID mapping ie mapping between
`1` and `2`. Example:- pool with name exists on
both the clusters with different ID's Replicapool
with ID `1` on site1 and Replicapool with ID `2`
on site2. After getting the required mapping Ceph-CSI
has the required information to get more details
from the rados OMAP. If we have multiple clusterID mapping
it will loop through all the mapping and checks the
corresponding pool to get the OMAP data. If the clusterID
mapping does not exist Ceph-CSI will return an `Not Found`
error message to the caller.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
The Go linter paralleltest checks that the t.Parallel
gets called for the test method and for the range of
test cases within the test.
Updates: #2025
Signed-off-by: Yati Padia <ypadia@redhat.com>
Current rbd plugin only supports the layering feature
for rbd image. Add exclusive-lock and journaling image
features for the rbd.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: woohhan <woohyung_han@tmax.co.kr>
as v1.0.0 is deprecated we need to remove the support
for it in the Next coming (v3.0.0) release. This PR
removes the support for the same.
closes#882
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
go-ceph v0.3 adds constants for ImageFeature values and their names.
Instead of hardcoding "layering" in several places, use the constant
given by librbd.
The rbdVolume.ImageFeatures does not seem to be used anywhere after the
conversion. Stashing the image metadata does include the ImageFeatures
as these are retrieved when getting the image information. It is safe to
drop ImageFeatures altogether and only use the imageFeatureSet instead.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The internal/ directory in Go has a special meaning, and indicates that
those packages are not meant for external consumption. Ceph-CSI does
provide public APIs for other projects to consume. There is no plan to
keep the API of the internally used packages stable.
Closes: #903
Signed-off-by: Niels de Vos <ndevos@redhat.com>