Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
https://github.com/ceph/go-ceph/pull/455/ added `state` field
to subvolume info struct which helps to identify the snapshot
retention state in the caller. This patch make use of the same
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
- mount host's /etc/selinux in node plugins
- process mount options in all code paths for cephfs volume options
Signed-off-by: Alexandre Lossent <alexandre.lossent@cern.ch>
This commit modifies the error of godot, cyclop,
paralleltest linter caused due to merged PRs.
Updates: #1586
Signed-off-by: Yati Padia <ypadia@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
Considering kubelet make sure the stage and publish operations
are serialized, we dont need any extra locking in nodePublish
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Considering kubelet make sure the unstage and unpublish operations
are serialized, we dont need any extra locking in nodeUnpublish
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
This commit resolves godot linter issue
which says "Comment should end in a period (godot)".
Updates: #1586
Signed-off-by: Yati Padia <ypadia@redhat.com>
We have many declarations and invocations..etc
with long lines which are very difficult to follow while doing
code reading. This address the issues in 'internal/cephfs' package to
restrict the line length to 120 chars.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
if it is an error from the IsMountPoint
function and the error is not IsNotExist return
it as a internal server error.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Currently we are relaying on the error output from
the umount command we run on the nodes when mounting
the volume but we are not checking for all the error
message to verify the volume is mounted or not.
This commits uses IsMountPoint function in util
to check the mountpoint.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
when using pre-provisioned volumes, pass these parameters:
- kernelMountOptions
- fuseMountOptions
- subVolumeGroup
in spec.csi.volumeAttributes in PV declaration
Signed-off-by: YingshuoTao <frigid.blues@gmail.com>
The CephFS NodeServer should handle the CephFS specific requests. This
is not something that the NodeServer for RBD should handle.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
nolint directive needs to be followed by comma separated
list of linters. This commit changes to gocognit:gocyclo
which was not recognised to linters which show error for
the function.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit appends stderr to error in both kernel and
ceph-fuse mounter functions to better be able to debug
errors.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit fixes bug in unmount function which caused
unmountVolume to fail when targetPath was already unmounted.
Signed-off-by: Rakshith R <rar@redhat.com>
Failed to delete voluesnapshot when backend subvolume
(pvc) and ceph fs subvolume snapshot is deleted
Fixes#1647
Signed-off-by: Yati Padia <ypadia@redhat.com>
as RBD is implementing the replication
we are registering it. For CephFS, its
not implementing the replication we are
passing nil so we dont want to register
it.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
when user provides an option for VolumeNamePrefix
create subvolume with the prefix which will be easy
for user to identify the subvolumes belongs to
the storageclass.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
There are many usecases with adding the subvolume
path to the PV object. the volume context returned
in the createVolumeResponse is added to the PV object
by the external provisioner.
More Details about the usecases are in below link
https://github.com/rook/rook/issues/5471
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This can happen when the subvolume is in snapshot-retained state.
We should not return error for such case as it is a valid situation.
Signed-off-by: Mudit Agarwal <muagarwa@redhat.com>
Currently, we are using bool pointer to find out
the ceph cluster supports resize or not. This
commit replaces the bool pointer with enum.
Signed-off-by: Yati Padia <ypadia@redhat.com>
Fixes#1764
The Owner of an RBD image (Kubernetes Namespace, tenant) can be used to
identify additional configuration options. This will be used for
fetching the right Vault Token when encrypting/decrypting volumes.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
clusterAdditionalInfo map is holding a localClusterState
for checking ceph cluster supports resize and subvolumegroup
is created or not, currently we are checking if the key is present
in a map and localClusterStatelocalClusterState.resizeSupported
is set to false to call ceph fs subvolume resize to check command is
supported or not, if a structure is initialized all its members
are set to default value. so we will never going to check the
ceph fs subvolume resize command is supported in backend or not, we are
always using ceph fs subvolume create to resize subvolume. in some
ceph version ceph fs subvolume create wont work to resize a subvolume.
This commit changes the resizeSupported from bool to *bool for
proper handling of this scenario.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
go ceph returns NotImplementedError for invalid
commands,cephcsi is using errors.As to find out
the error.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
go ceph returns NotImplementedError for invalid
commands,cephcsi is using errors.As to find out
the error.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
getCloneInfo() does not need to return a full CloneStatus struct that
only has one member. Instead, it can just return the value of the single
member, so the JSON type/struct does not need to be exposed.
This makes the API for getCloneInfo() a little simpler, so it can be
replaced by a go-ceph implementation later on.
As the function does not return any of the unused attributes anymore, it
is renamed to getCloneStatu() as well.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
incase of async mirroring the volume UUID is
retrieved from the volume name, instead of cephcsi
generating a new UUID it should reserve the passed
UUID it will be useful when we support both metro DR
and async mirroring on a kubernetes clusters.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The function isCloneRetryError verifies
if the clone error is `pending` or
`in-progress` error.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
In certain cases, clone status can be 'pending'.
In that case, abort error message should be
returned similar to that during 'in-progress'
state.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
There is a type-check on BytesQuota after calling SubVolumeInfo() to see
if the value is supported. In case no quota is configured, the value
Infinite is returned. This can not be converted to an int64, so the
original code returned an error.
It seems that attaching/mounting sometimes fails with the following
error:
FailedMount: MountVolume.MountDevice failed for volume "pvc-0e8fdd18-873b-4420-bd27-fa6c02a49496" : rpc error: code = Internal desc = subvolume csi-vol-0d68d71a-1f5f-11eb-96d2-0242ac110012 has unsupported quota: infinite
By ignoring the quota of Infinite, and not setting a quota in the
Subvolume object, this problem should not happen again.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
When using go-ceph and the volumeOptions.Connect() call, the credentials
are not needed once the connection is established.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Reduce the number of calls to the `ceph fs` executable to improve
performance of CephFS volume resizing.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
This prepares resizeVolume() so that the volumeOptions.conn can be used
for connecting with go-ceph and use the connection cache.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
golang-ci suddenly complains about the following issue
internal/cephfs/util.go:41:1: directive `// nolint:unparam // todo:program values has to be revisited later` is unused for linter unparam (nolintlint)
// nolint:unparam // todo:program values has to be revisited later
^
Dropping the comment completely seems to fix it. Ideally
execCommandJSON() will get removed once the migration to go-ceph is
complete.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Previously the purgeVolume error was ignored due to wrong error variable
check in the createVolume. With this change it checks on the proper error.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
The allocated, and potentially connected, volumeOptions object in
newVolumeOptionsFromVolID() is not cleaned-up in case of errors. This
could cause resource leaks.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Without connection, follow-up oparations on the volumeOptions object
will cause a panic. This should fix a regression in CephFS testing.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
There is no need to pass all secrets on to newVolumeOptions(), it only
needs the credentials. As the caller of newVolumeOptions() already has
the credentials generated, just pass them along instead of the raw
secrets.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The credentials are not used anymore, the volume object is already
connected to the cluster when createVolume() is called.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Add the ClusterConnection to the volumeOptions type, so that future use
of go-ceph can connect to the Ceph cluster.
Once a volumeOptions object is not needed anymore, it needs to get
destroyed to free associated resources like the ClusterConnection.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
return a proper error message to the user when
the subvolume has the snapshots and it cannot
be removed until the snapshots on the subvolume
have to be deleted.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
When passing
fuseMountOptions: debug
in the StorageClass, the mount options passed on the ceph-fuse
commandline result in "-o nonempty ,debug". The additional space before
the ",debug" causes the mount command to fail.
Fixes: 1485
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The subvolume features consists the list of features, which if includes
"snapshot-autoprotect", result in query based approach to
detecting the need for protect/unprotect.
If "snapshot-autoprotect" feature is present, The UnprotectSnapshot
call should be treated as a no-op
Signed-off-by: Yug <yuggupta27@gmail.com>
The subvolume features consists the list of features, which if includes
"snapshot-autoprotect", result in query based approach to
detecting the need for protect/unprotect.
If "snapshot-autoprotect" feature is present, The ProtectSnapshot
call should be treated as a no-op
Signed-off-by: Yug <yuggupta27@gmail.com>
Use subvolume info to fetch the subvolume path.
If `subvolume info` command is not available,
use `getpath` command instead.
Signed-off-by: Yug <yuggupta27@gmail.com>