genVolFromVolID() is used by the CSI Controller service to create an
rbdVolume object from a CSI volume_id. This function is useful for
CSI-Addons Services as well, so rename it to GenVolFromVolID().
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The dummy image will be created with 1Mib size.
during the snapshot transfer operation the 1Mib
will be transferred even if the dummy image doesnot
contains any data. adding the new image features
`fast-diff,layering,obj-map,exclusive-lock`on the
dummy image will ensure that only the diff is
transferred to the remote cluster.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
we added a workaround for rbd scheduling by creating
a dummy image in #2656. with the fix we are creating
a dummy image of the size of the first actual rbd
image which is sent in EnableVolumeReplication request
if the actual rbd image size is 1TiB we are creating
a dummy image of 1TiB which is not good. even though
its a thin provisioned rbd images this is causing
issue for the transfer of the snapshot during
the mirroring operation.
This commit recreates the rbd image with 1MiB size
which is the smaller supported size in rbd.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
rbd mirroring CLI calls are async and it doesn't wait
for the operation to be completed. ex:- `rbd mirror image enable`
it will enable the mirroring on the image but it doesn't
ensure that the image is mirroring enabled and healthy
primary. The same goes for the promote volume also.
This commits adds a check-in PromoteVolume to make sure
the image in a healthy state i.e `up+stopped`.
note:- not considering any intermediate states to make
sure the image is completely healthy before responding
success to the RPC call.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Journal-based RADOS block device mirroring ensures point-in-time
consistent replicas of all changes to an image, including reads and
writes, block device resizing, snapshots, clones, and flattening.
Journaling-based mirroring records all modifications to an image in the
order in which they occur. This ensures that a crash-consistent mirror
of an image is available.
Mirroring when configured in journal mode, mirroring will
utilize the RBD journaling image feature to replicate the image
contents. If the RBD journaling image feature is not yet enabled on the
image, it will be automatically enabled.
Fixes: #2018
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
currently we are fist operating on the dummy
image to refresh the pool and then we are adding
the scheduling. we think the scheduling should
be added first and than we should refresh the
pool. If we do this all the existing schedules
will be considered from the scheduler.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
with shallow copy of rbdVol to dummyVol
the image name update of the dummyVol is getting
reflected on the rbdVol which we dont want.
do deep copy to avoid this problem.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The dummy mirror image needs to be disabled and then
reenabled for mirroring, to ensure a newly promoted
primary is now starting to schedule snapshots.
Signed-off-by: Shyamsundar Ranganathan <srangana@redhat.com>
currently we have a bug in rbd mirror scheduling module.
After doing failover and failback the scheduling is not
getting updated and the mirroring snapshots are not
getting created periodically as per the scheduling
interval. This PR workarounds this one by doing below
operations
* Create a dummy (unique) image per cluster and this image
should be easily identified.
* During Promote operation on any image enable the
mirroring on the dummy image. when we enable the mirroring
on the dummy image the pool will get updated and the
scheduling will be reconfigured.
* During Demote operation on any image disable the mirroring
on the dummy image. the disable need to be done to enable
the mirroring again when we get the promote request to make
the image as primary
* When the DR is no more needed, this image need to be
manually cleanup as for now as we dont want to add a check
in the existing DeleteVolume code path for delete dummy image
as it impact the performance of the DeleteVolume workflow.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Moved to add scheduling to the promote
operation as scheduling need to be added
when the image is promoted and this is
the correct method of adding the scheduling
to make the scheduling take place.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
for comparing the image states use the states
defined in the go-ceph avoid creating of the
deplicate const in cephcsi.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
below are the local states of the mirrored image
"unknown" -> If the image is in an error state
means data is completely synced
"error" -> If the image is in an error state
means it needs resync
"syncing"
"starting_replay"
"replaying"
"stopping_replay"
"stopped"
If the resync is successfully started which
means the image will be in "replaying" state.
we can consider "replaying" state to report
resync succesfully going on state.
we are discarding the intermediate states like
"syncing", "starting_replay" and "stopping_replay".
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In some corner case like `re-player shutdown` the
local image will not be in error state. It would
be also worth considering `description` field to
make sure about split-brain.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Currently we return a !ready status if an image
is not found when a replication resync is issued.
We also return a !ready just post issuing a resync.
The change is to ensure we return errors in these
cases for the caller to retry the operation till
we can determine we are actually resyncing, and then
return !ready with nil errors.
Part of addressing:
https://github.com/csi-addons/volume-replication-operator/issues/101
Signed-off-by: Shyamsundar Ranganathan <srangana@redhat.com>
MirrorImageState (type C.rbd_mirror_image_state_t) has a string
method which can be used while returning error in the replication
controller. Previously, we were using int return in the error which
is not the proper usage.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
If the image is in secondary state and its
up+replaying means its an healthy secondary
and the image is primary somewhere in the remote
cluster and the local image is getting replayed.
Return success for the Disabling mirroring as
we cannot disable the mirroring on the secondary
state, when the image on the remote site gets
disabled the image on all the remote (secondary)
will get auto deleted. This helps in garbage
collecting the volume replication kuberentes
artifacts
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
consider the empty mirroring mode when
validating the snapshot interval and
the scheduling time.
Even if the mirroring Mode is not set
validate the snapshot scheduling details
as cephcsi sets the mirroring mode to default
snapshot.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Currently, getImageMirroringStatus() is using RBD CLI.
This commit converts RBD CLI to go-ceph API.
Fixes: #2120
Signed-off-by: Yati Padia <ypadia@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
Mirror-snapshots can also be automatically created on a
periodic basis if mirror-snapshot schedules are defined.
The mirror-snapshot can be scheduled globally, per-pool,
or per-image levels. Multiple mirror-snapshot schedules
can be defined at any level.
To create a mirror-snapshot schedule with rbd, specify
the mirror snapshot schedule add command along with an
optional pool or image name; interval; and optional start time:
The interval can be specified in days, hours, or minutes
using d, h, m suffix respectively. The optional start-time
can be specified using the ISO 8601 time format. For example:
```
$ rbd --cluster site-a mirror snapshot schedule
add --pool image-pool --image image1 24h 14:00:00-05:00
```
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in below files, and restrict the line length to 120 chars.
-internal/rbd/rbd_attach.go
-internal/rbd/rbd_journal.go
-internal/rbd/rbd_util.go
-internal/rbd/replicationcontrollerserver.go
-internal/rbd/snapshot.go
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
This commit addresses the following issue:
'nolint:gocyclo // complexity needs to be reduced.'
is unused for linter "gocyclo" (nolintlint)
Updates:#2025
Signed-off-by: Yati Padia <ypadia@redhat.com>
To recover from split brain (up+error) state the image need to be
demoted and requested for resync on site-a and then the image on site-b
should gets demoted.The volume should be marked to ready=true when the
image state on both the clusters are up+unknown because during the last
snapshot syncing the data gets copied first and then image state on the
site-a changes to up+unknown.
If the image state on both the sites are up+unknown consider that
complete data is synced as the last snapshot
gets exchanged between the clusters.
* create 10 GB of file and validate the data after resync
* Do Failover when the site-a goes down
* Force promote the image and write data in GiB
* Once the site-a comes back, Demote the image and issue resync
* Demote the image on site-b
* The status will get reflected on the other site when the last
snapshot sync happens
* The image will go to up+unknown state. and complete data will
be copied to site a
* Promote the image on site-a and use it
```bash
csi-vol-5633715e-a7eb-11eb-bebb-0242ac110006:
global_id: e7f9ec55-06ab-46cb-a1ae-784be75ed96d
state: up+unknown
description: remote image demoted
service: a on minicluster1
last_update: 2021-04-28 07:11:56
peer_sites:
name: e47e29f4-96e8-44ed-b6c6-edf15c5a91d6-rook-ceph
state: up+unknown
description: remote image demoted
last_update: 2021-04-28 07:11:41
```
* Do Failover when the site-a goes down
* Force promote the image on site-b and write data in GiB
* Demote the image on site-b
* Once the site-a comes back, Demote the image on site-a
* The images on the both site will go to split brain state
```bash
csi-vol-37effcb5-a7f1-11eb-bebb-0242ac110006:
global_id: 115c3df9-3d4f-4c04-93a7-531b82155ddf
state: up+error
description: split-brain
service: a on minicluster2
last_update: 2021-04-28 07:25:41
peer_sites:
name: abbda0f0-0117-4425-8cb2-deb4c853da47-rook-ceph
state: up+error
description: split-brain
last_update: 2021-04-28 07:25:26
```
* Issue resync
* The images cannot be resynced because when we issue resync
on site a the image on site-b was in demoted state
* To recover from this state (promote and then demote the
image on site-b after sometime)
```bash
csi-vol-37effcb5-a7f1-11eb-bebb-0242ac110006:
global_id: 115c3df9-3d4f-4c04-93a7-531b82155ddf
state: up+unknown
description: remote image demoted
service: a on minicluster1
last_update: 2021-04-28 07:32:56
peer_sites:
name: e47e29f4-96e8-44ed-b6c6-edf15c5a91d6-rook-ceph
state: up+unknown
description: remote image demoted
last_update: 2021-04-28 07:32:41
```
* Once the data is copied we can see that the image state
is moved to up+unknown on both sites
* Promote the image on site-a and use it
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
incase if the image is promoted and demoted the
image state will be set to up+unknown if the image
on the remote cluster is still in demoted state.
when user changes the state from primary to secondary
and still the image is in demoted (secondary) state
in the remote cluster. the image state on both the cluster
will be on unknown state.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In case of the DR the image on the primary site cannot be
demoted as the cluster is down, during failover the image need
to be force promoted. RBD returns `Device or resource busy`
error message if the image cannot be promoted for above reason.
Return FailedPrecondition so that replication operator can send
request to force promote the image.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
instead of fetching the force option from the
parameters. Use the Force field available in
the PromoteVolume Request.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
as the org github.com/kube-storage is renamed
to github.com/csi-addons as the name kube-storage
was more generic.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Incase of resync the image will get deleted, gets
recreated and its a a time consuming operation.
It makes sense to return aborted error instead
of not found as we have omap data only the image
is missing in rbd pool.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Do resync if the image is in unknow or in error
state.
Check for the current image state for up+stopped
or up+replaying and also all peer site status
should be un up+stopped to confirm that resyncing
is done and image can be promoted and used.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
the rbd mirror state can be in enabled,disabled
or disabling state. If the mirroring is not disabled
yet and still in disabling state. we need to
check for it and return abort error message if
the mirroring is still getting disabled.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
added ReplicationServer struct for the replication related
operation it also embed the ControllerServer which
already implements the helper functions like locking/unlocking etc.
removed getVolumeFromID and cleanup functions for better
code readability and easy maintaince.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>