We have below exported function in credentials.go which is not
called from anywhere in the repo. Removing it for the same reason.
```
// NewCredentials generates new credentials when id and key
// are provided.
func NewCredentials(id, key string) (*Credentials, error) {
...
```
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
`cap` builtin function returns the capacity of a type. Its not
good practice to use this builtin function for other variable
names, removing it here
Ref# https://golang.org/pkg/builtin/#cap
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
golang-ci suddenly complains about the following issue
internal/cephfs/util.go:41:1: directive `// nolint:unparam // todo:program values has to be revisited later` is unused for linter unparam (nolintlint)
// nolint:unparam // todo:program values has to be revisited later
^
Dropping the comment completely seems to fix it. Ideally
execCommandJSON() will get removed once the migration to go-ceph is
complete.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
volJournal.Connect() got the error on err2 variable, however
the return was on variable err which hold the error return of
DecomposeCSIID() which is wrong. This cause the error return wrongly
parsed and pushed from the caller. From now on, we are reusing the
err variable to hold and revert the error of volJournal.Connect().
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Previously the purgeVolume error was ignored due to wrong error variable
check in the createVolume. With this change it checks on the proper error.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
The allocated, and potentially connected, volumeOptions object in
newVolumeOptionsFromVolID() is not cleaned-up in case of errors. This
could cause resource leaks.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Without connection, follow-up oparations on the volumeOptions object
will cause a panic. This should fix a regression in CephFS testing.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
All the previous condition checks exit from the function and
when it reach to this block its obvious that error is non nil,
we dont need an extra check here.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
There is no need to pass all secrets on to newVolumeOptions(), it only
needs the credentials. As the caller of newVolumeOptions() already has
the credentials generated, just pass them along instead of the raw
secrets.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The credentials are not used anymore, the volume object is already
connected to the cluster when createVolume() is called.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The go-ceph CephFS Admin API needs a rados.Conn to connect the Admin
interface to the Ceph cluster. As the rados.Conn is internal to the
ClusterConnection type, add GetFSAdmin() to create a new FSAdmin
instance for a specific connection.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Add the ClusterConnection to the volumeOptions type, so that future use
of go-ceph can connect to the Ceph cluster.
Once a volumeOptions object is not needed anymore, it needs to get
destroyed to free associated resources like the ClusterConnection.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The error check condition in genVolFromID() is always false as far as
code reading/workflow goes. Removing it for the same reason.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
cephcsi uses cli for fetching snap list as well as to check the
snapshot namespace, replaced that with go-ceph calls.
Signed-off-by: Mudit Agarwal <muagarwa@redhat.com>
return a proper error message to the user when
the subvolume has the snapshots and it cannot
be removed until the snapshots on the subvolume
have to be deleted.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
When passing
fuseMountOptions: debug
in the StorageClass, the mount options passed on the ceph-fuse
commandline result in "-o nonempty ,debug". The additional space before
the ",debug" causes the mount command to fail.
Fixes: 1485
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The subvolume features consists the list of features, which if includes
"snapshot-autoprotect", result in query based approach to
detecting the need for protect/unprotect.
If "snapshot-autoprotect" feature is present, The UnprotectSnapshot
call should be treated as a no-op
Signed-off-by: Yug <yuggupta27@gmail.com>
The subvolume features consists the list of features, which if includes
"snapshot-autoprotect", result in query based approach to
detecting the need for protect/unprotect.
If "snapshot-autoprotect" feature is present, The ProtectSnapshot
call should be treated as a no-op
Signed-off-by: Yug <yuggupta27@gmail.com>
Use subvolume info to fetch the subvolume path.
If `subvolume info` command is not available,
use `getpath` command instead.
Signed-off-by: Yug <yuggupta27@gmail.com>
Snapshots can be retained even after subvolume deletion in
Ceph 14.2.12. Adding support for the same in ceph-csi.
Signed-off-by: Yug <yuggupta27@gmail.com>
It doesnot make sense to allow the creation of empty
volumes with readonly access, this commit allows the
creation of volume which is having readonly capabilities
only if the content source is set for the volume.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
It doesnot make sense to allow the creation of empty
volumes which is going to be accessed with readonly mode,
this commit allows the creation of volume which is having
readonly capabilities only if the content source is set
for the volume.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This spec add the extra capability to node and controller
volume to report volume condition of a pv..etc.
Refer # https://github.com/ceph/ceph-csi/issues/1356
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>