- gomnd is replaced by mnd in v1.58.0
- gosec exlcude G115 rule (Potential integer overflow when converting between integer types)
- disable new iface linter
- disable new recvcheck linter
Signed-off-by: Praveen M <m.praveen@ibm.com>
using os.RemoveAll will remove everything
in the director after the Umount we should
be using os.Remove only to remove the empty
directory
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
We should not be dependent on the CO to ensure
that it will serialize the request instead of
that we need to have own internal locks to ensure
that we dont do concurrent operations for same
request.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
rbd nodeserver is already setting
volume condition in NodeGetVolumeStats
RPC call but the cap is not updated
for it, This PR advertise the
VOLUME_CONDITION
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In the future we'll introduce a more standard interface for objects like
Volumes and Snapshots. It is useful to have the context passed as 1st
argument to all functions of those objects, including their Destroy()
function.
Signed-off-by: Niels de Vos <ndevos@ibm.com>
This commit makes use of crush location labels from node
labels to supply `crush_location` and `read_from_replica=localize`
options during mount. Using these options, cephfs
will be able to redirect reads to the closest OSD,
improving performance.
Signed-off-by: Praveen M <m.praveen@ibm.com>
Implemented the capability to include read affinity options
for individual clusters within the ceph-csi-config ConfigMap.
This allows users to configure the crush location for each
cluster separately. The read affinity options specified in
the ConfigMap will supersede those provided via command line arguments.
Signed-off-by: Praveen M <m.praveen@ibm.com>
When a volume has AccessType=Block and is encrypted with LUKS, a resize
of the filesystem on the (decrypted) block-device is attempted. This
should not be done, as the application that requested the Block volume
is the only authoritive reader/writer of the data.
In particular VirtualMachines that use RBD volumes as a disk, usually
have a partition table on the disk, instead of only a single filesystem.
The `resizefs` command will not be able to resize the filesystem on the
block-device, as it is a partition table.
When `resizefs` fails during NodeStageVolume, the volume is unstaged and
an error is returned.
Resizing an encrypted block-device requires `cryptsetup resize` so that
the LUKS header on the RBD-image is updated with the correct size. But
there is no need to call `resizefs` in this case.
Fixes: #3945
Signed-off-by: Niels de Vos <ndevos@ibm.com>
Add `mkfsOptions` to the StorageClass and pass them to the `mkfs`
command while creating the filesystem on the RBD device.
Fixes: #374
Signed-off-by: Niels de Vos <ndevos@ibm.com>
Storing the default `mkfs` arguments in a map with key per filesystem
type makes this a little more modular. It prepares th code for fetching
the `mkfs` arguments from the VolumeContext.
Signed-off-by: Niels de Vos <ndevos@ibm.com>
This commit makes use of crush location labels from node
labels to supply `crush_location` and `read_from_replica=localize`
options during rbd map cmd. Using these options, ceph
will be able to redirect reads to the closest OSD,
improving performance.
Signed-off-by: Rakshith R <rar@redhat.com>
The StagingTargetPath is an optional entry in
NodeExpandVolumeRequest, We cannot expect it to be
set always and at the same time cephcsi depended
on the StaingTargetPath to retrieve some metadata
information.
This commit will check all the mount ref and identifies
the stagingTargetPath by checking the image-meta.json
file exists and this is a costly operation as we need to
loop through all the mounts and check image-meta.json
in each mount but this is happens only if the
StaingTargetPath is not set in the NodeExpandVolumeRequest
fixes#3623
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
set disableInUseChecks on rbd volume struct
as it will be used later to check whether
the rbd image is allowed to mount on multiple
nodes.
fixes: #3604
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Checking volume details for the existing volumeID
first. if details like OMAP, RBD Image, Pool doesnot
exists try to use clusterIDMapping to look for the
correct informations.
fixes: #2929
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
When we do stat on the targetpath, if there is
any error we can check is it due to corruption.
If yes, cephcsi can return abnormal in the
NodeGetVolumeStats so that consumer (CO/admin)
and detect and take further action.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Integrate basic fscrypt functionality into RBD initialization. To
activate file encryption instead of block introduce the new
'encryptionType' storage class key.
Signed-off-by: Marcel Lauhoff <marcel.lauhoff@suse.com>
In preparation of fscrypt support for RBD filesystems, rename block
encryption related function to include the word 'block'. Add struct
fields and IsFileEncrypted.
Signed-off-by: Marcel Lauhoff <marcel.lauhoff@suse.com>
CephFS does not have a concept of "free inodes", inodes get allocated
on-demand in the filesystem.
This confuses alerting managers that expect a (high) number of free
inodes, and warnings get produced if the number of free inodes is not
high enough. This causes alerts to always get reported for CephFS.
To prevent the false-positive alerts from happening, the
NodeGetVolumeStats procedure for CephFS (and CephNFS) will not contain
inodes in the reply anymore.
See-also: https://bugzilla.redhat.com/2128263
Signed-off-by: Niels de Vos <ndevos@redhat.com>
IsNotMountPoint() is deprecated and Mounter.IsMountPoint() is
recommended to be used instead.
Reported-by: golangci/staticcheck
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Recently the k8s.io/mount-utils package added more runtime dectection.
When creating a new Mounter, the detect is run every time. This is
unfortunate, as it logs a message like the following:
```
mount_linux.go:283] Detected umount with safe 'not mounted' behavior
```
This message might be useful, so it probably good to keep it.
In Ceph-CSI there are various locations where Mounter instances are
created. Moving that to the DefaultNodeServer type reduces it to a
single place. Some utility functions need to accept the additional
parameter too, so that has been modified as well.
See-also: kubernetes/kubernetes#109676
Signed-off-by: Niels de Vos <ndevos@redhat.com>
There are regular reports that identify a non-error as the cause of
failures. The Kubernetes mount-utils package has detection for systemd
based environments, and if systemd is unavailable, the following error
is logged:
Cannot run systemd-run, assuming non-systemd OS
systemd-run output: System has not been booted with systemd as init
system (PID 1). Can't operate.
Failed to create bus connection: Host is down, failed with: exit status 1
Because of the `failed` and `exit status 1` error message, users might
assume that the mounting failed. This does not need to be the case. The
container-images that the Ceph-CSI projects provides, do not use
systemd, so the error will get logged with each mount attempt.
By using the newer MountSensitiveWithoutSystemd() function from the
mount-utils package where we can, the number of confusing logs get
reduced.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
krbdFeatures is set to zero when kernel version < 3.8, i.e. in case where
/sys/bus/rbd/supported_features is absent and we are unable to prepare
the krbd attributes based on kernel version.
When krbdFeatures is set to zero fallback to NBD only when autofallback
is turned ON.
Fixes: #2678
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
For the default mounter the mounter option
will not be set in the storageclass and as it is
not available in the storageclass same will not
be set in the volume context, Because of this the
mapOptions are getting discarded. If the mounter
is not set assuming it's an rbd mounter.
Note:- If the mounter is not set in the storageclass
we can set it in the volume context explicitly,
Doing this check-in node server to support backward
existing volumes and the check is minimal we are not
altering the volume context.
fixes: #3076
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
As the netNamespaceFilePath can be separate for
both cephfs and rbd adding the netNamespaceFilePath
path for RBD, This will help us to keep RBD and
CephFS specific options separately.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
add support to run rbd map and mount -t
commands with the nsenter.
complete design of pod/multus network
is added here https://github.com/rook/rook/
blob/master/design/ceph/multus-network.md#csi-pods
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Below are the 3 different cases where we need
the PVC namespace for encryption
* CreateVolume:- Read the namespace from the
createVolume parameters and store it in the omap
* NodeStage:- Read the namespace from the omap
not from the volumeContext
* Regenerate:- Read the pvc namespace from the claimRef
not from the volumeAttributes.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Makes the rbd images features in the storageclass
as optional so that default image features of librbd
can be used. and also kept the option to user
to specify the image features in the storageclass.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This commit removes the thick provisioning
code as thick provisioning is deprecated in
cephcsi 3.5.0.
fixes: #2795
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
currently we are overriding the permission to `0o777` at time of node
stage which is not the correct action. That said, this permission
change causes an extra permission correction at time of nodestaging
by the CO while the FSGROUP change policy has been set to
`OnRootMismatch`.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
With introduction of go-ceph rbd admin task api, credentials are
no longer required to be passed as cli cmd is not invoked.
Signed-off-by: Rakshith R <rar@redhat.com>
If the volume with a bigger size is created
from a snapshot or from another volume we
need to exapand the filesystem also in the
csidriver as nodeExpand request is not triggered
for this one, During NodeStageVolume we can
expand the filesystem by checking filesystem
needs expansion or not.
If its a encrypted device, check the device
size of rbd device and the LUKS device if required
the device will be expanded before
expanding the filesystem.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
NodeServer.mounter is internal to the NodeServer type, but it needs to
be initialized by the rbd-driver. The rbd-driver is moved to its own
package, so .Mounter needs to be available from there in order to set
it.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Uses the below schema to supply mounter specific map/unmapOptions to the
nodeplugin based on the discussion we all had at
https://github.com/ceph/ceph-csi/pull/2636
This should specifically be really helpful with the `tryOthermonters`
set to true, i.e with fallback mechanism settings turned ON.
mapOption: "kbrd:v1,v2,v3;nbd:v1,v2,v3"
- By omitting `krbd:` or `nbd:`, the option(s) apply to
rbdDefaultMounter which is krbd.
- A user can _override_ the options for a mounter by specifying `krbd:`
or `nbd:`.
mapOption: "v1,v2,v3;nbd:v1,v2,v3"
is effectively the same as the 1st example.
- Sections are split by `;`.
- If users want to specify common options for both `krbd` and `nbd`,
they should mention them twice.
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>