For core K8s API objects like Pods, Nodes, etc., we
can use protobuf encoding which reduces CPU consumption
related to (de)serialization, reduces overall latency
of the API call, reduces memory footprint, reduces the
amount of work performed by the GC and results in quicker
propagation of objects to event handlers of shared informers.
Signed-off-by: Nikhil-Ladha <nikhilladha1999@gmail.com>
There has been some confusion about using different variables for the
InstanceID of the RBD-driver. By removing the global variable
CSIInstanceID, there should be no confusion anymore what variable to
use.
Signed-off-by: Niels de Vos <ndevos@ibm.com>
MetricsBindAddress is replaced by Metrics in the
controller-runtime manager options in version 0.16.0
as part of
e59161ee8f
Updating the same here.
Signed-off-by: karthik-us <ksubrahm@redhat.com>
There is no release for sigs.k8s.io/controller-runtime that supports
Kubernetes v1.27. The main branch has all the required modifications, so
we can use that for the time being.
Signed-off-by: Niels de Vos <ndevos@ibm.com>
Address: hugeParam linter
internal/controller/persistentvolume/persistentvolume.go:59:7:
hugeParam: r is heavy (80 bytes); consider passing it by pointer
(gocritic)
[...]
internal/controller/persistentvolume/persistentvolume.go:135:7:
hugeParam: r is heavy (80 bytes); consider passing it by pointer
(gocritic)
func (r ReconcilePersistentVolume) reconcilePV(ctx context.Context, obj
runtime.Object) error {}
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
As we added support to set the metadata on the rbd images created for
the PVC and volume snapshot, by default metadata is set on all the images.
As we have seen we are hitting issues#2327 a lot of times with this,
we start to leave a lot of stale images. Currently, we rely on
`--extra-create-metadata=true` to decide to set the metadata or not,
we cannot set this option to false to disable setting metadata because we
use this for encryption too.
This changes is to provide an option to disable setting the image
metadata when starting cephcsi.
Fixes: #3009
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
This change helps read the cluster name from the cmdline args,
the provisioner will set the same on the RBD images.
Fixes: #2973
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
use leases for leader election instead
of the deprecated configmap based leader
election.
This PR is making leases as default leader election
refer https://github.com/kubernetes-sigs/
controller-runtime/pull/1773, default from configmap
to configmap leases was done with
https://github.com/kubernetes-sigs/
controller-runtime/pull/1144.
Release notes https://github.com/kubernetes-sigs/
controller-runtime/releases/tag/v0.7.0
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Example if a PVC was delete by setting `persistentVolumeReclaimPolicy` as
`Retain` on PV, and PV is reattached to a new PVC, we make sure to update
PV/PVC image metadata on a PV reattach.
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
Below are the 3 different cases where we need
the PVC namespace for encryption
* CreateVolume:- Read the namespace from the
createVolume parameters and store it in the omap
* NodeStage:- Read the namespace from the omap
not from the volumeContext
* Regenerate:- Read the pvc namespace from the claimRef
not from the volumeAttributes.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
we have added clusterID mapping to identify the volumes
in case of a failover in Disaster recovery in #1946.
with #2314 we are moving to a configuration in
configmap for clusterID and poolID mapping.
and with #2314 we have all the required information
to identify the image mappings.
This commit removes the workaround implementation done
in #1946.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
checkStaticVolume() in the reconcilePV function has been unwantedly
introducing variables to confirm the pv spec is static or not. This
patch simplify it and make a smaller footprint of the functions.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
ContollerManager had a typo in it, and if we correct it,
linter will fail and suggest not to use controller.ControllerManager
as the interface name and package name is redundant, keeping manager
as the interface name which is the practice and also address the
linter issues.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
This commit refractors RegenerateJournal() to take in
volumeAttributes map[string]string as argument so it
can extract required attributes internally.
Signed-off-by: Rakshith R <rar@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
This commit updates controller-runtime to v0.9.2 and
makes changes in persistentvolume.go to add context to
various functions and function calls made here instead of
context.TODO().
Signed-off-by: Rakshith R <rar@redhat.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in 'internal/controller' package to restrict the line length to 120 chars.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Wrapcheck is a simple Go linter to check that errors
from external packages are wrapped during return to
help identify the error source during debugging.
This commit addresses the wrapcheck error
Updates:#2025
Signed-off-by: Yati Padia <ypadia@redhat.com>
there can be a change we can reconcile same
PV parallelly we can endup in generating and
deleting multiple omap keys. to be on safer
side taking lock to process one volumeHandle
at a time.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In the case of the Async DR, the volumeID will
not be the same if the clusterID or the PoolID
is different, With Earlier implementation, it
is expected that the new volumeID mapping is
stored in the rados omap pool. In the case of the
ControllerExpand or the DeleteVolume Request,
the only volumeID will be sent it's not possible
to find the corresponding poolID in the new cluster.
With This Change, it works as below
The csi-rbdplugin-controller will watch for the PV
objects, when there are any PV objects created it
will check the omap already exists, If the omap doesn't
exist it will generate the new volumeID and it checks for
the volumeID mapping entry in the PV annotation, if the
mapping does not exist, it will add the new entry
to the PV annotation.
The cephcsi will check for the PV annotations if the
omap does not exist if the mapping exists in the PV
annotation, it will use the new volumeID for further
operations.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
if the user has created a static PV for a RBD
image which is not created by CSI driver, dont
generate the OMAP data.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In the case of Disaster Recovery failover, the
user expected to create the static PVC's. We have
planned not to go with the PVC name and namespace
for many reasons (as in kubernetes it's planned to
support PVC transfer to a new namespace with a
different name and with new features coming in
like data populator etc). For now, we are
planning to go with static PVC's to support
async mirroring.
During Async mirroring only the RBD images are
mirrored to the secondary site, and when the
user creates the static PVC's on the failover
we need to regenerate the omap data. The
volumeHandler in PV spec is an encoded string
which contains clusterID and poolID and image UUID,
The clusterID and poolID won't remain same on both
the clusters, for that cephcsi need to generate the
new volume handler and its to create a mapping
between new volume handler and old volume handler
with that whenever cephcsi gets csi requests it
check if the mapping exists it will pull the new
volume handler and continues other operations.
The new controller watches for the PVs created,
It checks if the omap exists if it doesn't it
will regenerate the entire omap data.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>