Following the CSI specification, values that are included in the
VolumeUsage MUST NOT be negative. However, CephFS seems to return -1 for
the number of inodes that are available. Instead of returning a
negative value, set it to 0 so that it will not get included in the
encoded JSON response.
Updates: #2579
See-also: 5b0d454015/spec.md (L2477-L2487)
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in 'internal/csi-common' package to restrict the line length to 120 chars.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
The Go linter paralleltest checks that the t.Parallel
gets called for the test method and for the range of
test cases within the test.
Updates: #2025
Signed-off-by: Yati Padia <ypadia@redhat.com>
as callers are already taking care of returing
the GRPC error code return the actual error
from the IsMountPoint function.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This commit addresses ifshort linter issues which
checks if short syntax for if-statements is possible.
updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
The CephFS NodeServer should handle the CephFS specific requests. This
is not something that the NodeServer for RBD should handle.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Currently default ControllerGetCapabilities function is being
used which throws 'runtime error: invalid memory address or
nil pointer dereference' when `--controllerServer=true` is not
set in provisioner deployment args.
This commit adds a check to prevent it.
Fixes: 1925
Signed-off-by: Rakshith R <rar@redhat.com>
as the org github.com/kube-storage is renamed
to github.com/csi-addons as the name kube-storage
was more generic.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
as RBD is implementing the replication
we are registering it. For CephFS, its
not implementing the replication we are
passing nil so we dont want to register
it.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This spec add the extra capability to node and controller
volume to report volume condition of a pv..etc.
Refer # https://github.com/ceph/ceph-csi/issues/1356
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Direct usage of numbers should be avoided.
Issue reported:
mnd: Magic number: X, in <argument> detected (gomnd)
Signed-off-by: Yug <yuggupta27@gmail.com>
if the PVC access mode is ReadOnlyMany
or single node readonly, mounting the rbd
device path to the staging path as readonly
to avoid the write operation.
If the PVC acccess mode is readonly, mapping
rbd images as readonly.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The internal/ directory in Go has a special meaning, and indicates that
those packages are not meant for external consumption. Ceph-CSI does
provide public APIs for other projects to consume. There is no plan to
keep the API of the internally used packages stable.
Closes: #903
Signed-off-by: Niels de Vos <ndevos@redhat.com>