The VolumeGroupJournal interface does not need to return anything except
for a potential error. Any instance that implements the
VolumeGroupJournal interface can be used to call all functions.
Signed-off-by: Niels de Vos <ndevos@ibm.com>
Implement the required function to store/retrieve
the details from the omap for the volumegroup.
This adds a new omap object that contains the
mapping of the RequestName and all the volumeID
and its corresponding snapshotID belonging to a
group.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Added a implementation for the listOmapVals
which list the object keys and values from
the rados omap.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
If a PV is reattached to a new PVC in a different
namespace we need to update the namespace name
in the rados object.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The github.com/google/uuid package is used by Kubernetes, and it is part
of the vendor/ directory already. Our usage of github.com/pborman/uuid
can be replaced by github.com/google/uuid, so that
github.com/pborman/uuid can be removed as a dependency.
Closes: #3315
Signed-off-by: Niels de Vos <ndevos@redhat.com>
This commit implements most of
docs/design/proposals/cephfs-snapshot-shallow-ro-vol.md design document;
specifically (de-)provisioning of snapshot-backed volumes, mounting such
volumes as well as mounting pre-provisioned snapshot-backed volumes.
Signed-off-by: Robert Vasek <robert.vasek@cern.ch>
at present, eventhough the checkReservation works for both volume
and snapshot, the arg parentName make sense only for snapshot cases
renaming that arg to more approprite
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
revive linter checks for var-declaration
format.
For example:
"e2e/rbd_helper.go:441:36: var-declaration:
should drop = nil from declaration of
var noPVCValidation; it is the zero value (revive)
var noPVCValidation validateFunc = nil"
Updates: #1586
Signed-off-by: Yati Padia <ypadia@redhat.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in 'internal/journal' package to restrict the line length to 120 chars.
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
Wrapcheck is a simple Go linter to check that errors
from external packages are wrapped during return to
help identify the error source during debugging.
This commit addresses the wrapcheck error
Updates:#2025
Signed-off-by: Yati Padia <ypadia@redhat.com>
The Owner of an RBD image (Kubernetes Namespace, tenant) can be used to
identify additional configuration options. This will be used for
fetching the right Vault Token when encrypting/decrypting volumes.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
In the case of Disaster Recovery failover, the
user expected to create the static PVC's. We have
planned not to go with the PVC name and namespace
for many reasons (as in kubernetes it's planned to
support PVC transfer to a new namespace with a
different name and with new features coming in
like data populator etc). For now, we are
planning to go with static PVC's to support
async mirroring.
During Async mirroring only the RBD images are
mirrored to the secondary site, and when the
user creates the static PVC's on the failover
we need to regenerate the omap data. The
volumeHandler in PV spec is an encoded string
which contains clusterID and poolID and image UUID,
The clusterID and poolID won't remain same on both
the clusters, for that cephcsi need to generate the
new volume handler and its to create a mapping
between new volume handler and old volume handler
with that whenever cephcsi gets csi requests it
check if the mapping exists it will pull the new
volume handler and continues other operations.
The new controller watches for the PVs created,
It checks if the omap exists if it doesn't it
will regenerate the entire omap data.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
incase of async mirroring the volume UUID is
retrieved from the volume name, instead of cephcsi
generating a new UUID it should reserve the passed
UUID it will be useful when we support both metro DR
and async mirroring on a kubernetes clusters.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The implementation of getOMapValues assumed that the number of key-value
pairs assigned to the object would be close to the number of keys
being requested. When the number of keys on the object exceeded the
"listExcess" value the function would fail to read additional keys
even if they existed in the omap.
This change sets a large fixed "chunk size" value and keeps reading
key-value pairs as long as the callback gets called and increments
the numKeys counter.
Signed-off-by: John Mulligan <jmulligan@redhat.com>
Make sure to operate within the namespace if any given
when dealing with rbd images and snapshots and their journals.
Signed-off-by: Mehdy Khoshnoody <mehdy.khoshnoody@gmail.com>
The sentinel error code had additional fields in the errors, that are
used nowhere. This leads to unneccesarily complicated code. This
change replaces the sentinel errors in utils with standard errors
created with errors.New() and adds a simple JoinErrors() function to
be able to combine sentinel errors from different code tiers.
Related: #1203
Signed-off-by: Sven Anderson <sven@redhat.com>
Direct usage of numbers should be avoided.
Issue reported:
mnd: Magic number: X, in <argument> detected (gomnd)
Signed-off-by: Yug <yuggupta27@gmail.com>
Several places in the code compared errors directly with the go-ceph
sentinel errors. This change uses the errors.Is() function of go
1.13 instead. The err113 linter reported this issue as:
err113: do not compare errors directly, use errors.Is() instead
Signed-off-by: Sven Anderson <sven@redhat.com>
"github.com/pkg/errors" does not offer more functionlity than that we
need from the standard "errors" package. With Golang v1.13 errors can be
wrapped with `fmt.Errorf("... %w", err)`. `errors.Is()` and
`errors.As()` are available as well.
See-also: https://tip.golang.org/doc/go1.13#error_wrapping
Signed-off-by: Niels de Vos <ndevos@redhat.com>
cephcsi need to store and retrieve the rbd image ID
in the omap as we need the image ID to add a
task to remove the image from the Trash.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
The previous function used to remove omap keys apparently did not
return errors when removing omap keys from a missing omap (oid).
Mimic that behavior when using the api.
Signed-off-by: John Mulligan <jmulligan@redhat.com>
For any function that sets more than one key on a single oid setting
them as a batch will be more efficient.
Signed-off-by: John Mulligan <jmulligan@redhat.com>
For any function that removes more than one key on a single oid removing
them as a batch will be more efficient.
Signed-off-by: John Mulligan <jmulligan@redhat.com>
Taking this appraoch means that any function that must get more than one
key's value from the same oid can be more efficient by calling out to
ceph only once.
To be cautious and avoid missing things we always request ceph return
more keys than we actually expect to be set on the oid. If there are
unexpected keys there, we will not miss the keys we want if we first hit
an unexpected key if we were to limit ourselves to iterating only over
the number of keys we're expecting to be on the object.
Signed-off-by: John Mulligan <jmulligan@redhat.com>