/* Copyright 2021 The Ceph-CSI Authors. Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except in compliance with the License. You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. */ package e2e import ( "context" "fmt" "strconv" "strings" v1 "k8s.io/api/core/v1" "k8s.io/apimachinery/pkg/api/resource" metav1 "k8s.io/apimachinery/pkg/apis/meta/v1" "k8s.io/kubernetes/test/e2e/framework" ) const ( staticPVSize = "4Gi" staticPVNewSize = "8Gi" staticPVImageFeature = "layering" monsPrefix = "mons-" imagePrefix = "image-" migIdentifier = "mig" intreeVolPrefix = "kubernetes-dynamic-pvc-" ) func getStaticPV( name, volName, size, secretName, secretNS, sc, driverName string, blockPV bool, options, annotations map[string]string, policy v1.PersistentVolumeReclaimPolicy, ) *v1.PersistentVolume { pv := &v1.PersistentVolume{ ObjectMeta: metav1.ObjectMeta{ Name: name, }, Spec: v1.PersistentVolumeSpec{ PersistentVolumeReclaimPolicy: policy, Capacity: v1.ResourceList{ v1.ResourceStorage: resource.MustParse(size), }, PersistentVolumeSource: v1.PersistentVolumeSource{ CSI: &v1.CSIPersistentVolumeSource{ Driver: driverName, VolumeHandle: volName, ReadOnly: false, VolumeAttributes: options, NodeStageSecretRef: &v1.SecretReference{ Name: secretName, Namespace: secretNS, }, }, }, StorageClassName: sc, AccessModes: []v1.PersistentVolumeAccessMode{v1.ReadWriteOnce}, }, } if blockPV { volumeMode := v1.PersistentVolumeBlock pv.Spec.VolumeMode = &volumeMode } else { volumeMode := v1.PersistentVolumeFilesystem pv.Spec.VolumeMode = &volumeMode } if len(annotations) > 0 { pv.Annotations = make(map[string]string) for k, v := range annotations { pv.Annotations[k] = v } } return pv } func getStaticPVC(name, pvName, size, ns, sc string, blockPVC bool) *v1.PersistentVolumeClaim { pvc := &v1.PersistentVolumeClaim{ ObjectMeta: metav1.ObjectMeta{ Name: name, Namespace: ns, }, Spec: v1.PersistentVolumeClaimSpec{ Resources: v1.VolumeResourceRequirements{ Requests: v1.ResourceList{ v1.ResourceStorage: resource.MustParse(size), }, }, AccessModes: []v1.PersistentVolumeAccessMode{v1.ReadWriteOnce}, VolumeName: pvName, StorageClassName: &sc, }, } if blockPVC { volumeMode := v1.PersistentVolumeBlock pvc.Spec.VolumeMode = &volumeMode } else { volumeMode := v1.PersistentVolumeFilesystem pvc.Spec.VolumeMode = &volumeMode } return pvc } func validateRBDStaticPV(f *framework.Framework, appPath string, isBlock, checkImgFeat bool) error { opt := make(map[string]string) var ( rbdImageName = "test-static-pv" pvName = "pv-name" pvcName = "pvc-name" namespace = f.UniqueName // minikube creates default class in cluster, we need to set dummy // storageclass on PV and PVC to avoid storageclass name mismatch sc = "storage-class" ) c := f.ClientSet fsID, err := getClusterID(f) if err != nil { return fmt.Errorf("failed to get clusterID: %w", err) } size := staticPVSize // create rbd image cmd := fmt.Sprintf( "rbd create %s --size=%s --image-feature=layering %s", rbdImageName, staticPVSize, rbdOptions(defaultRBDPool)) _, e, err := execCommandInToolBoxPod(f, cmd, rookNamespace) if err != nil { return err } if e != "" { return fmt.Errorf("failed to create rbd image %s", e) } opt["clusterID"] = fsID if !checkImgFeat { opt["imageFeatures"] = staticPVImageFeature } opt["pool"] = defaultRBDPool opt["staticVolume"] = strconv.FormatBool(true) if radosNamespace != "" { opt["radosNamespace"] = radosNamespace } pv := getStaticPV( pvName, rbdImageName, size, rbdNodePluginSecretName, cephCSINamespace, sc, "rbd.csi.ceph.com", isBlock, opt, nil, retainPolicy) _, err = c.CoreV1().PersistentVolumes().Create(context.TODO(), pv, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("PV Create API error: %w", err) } pvc := getStaticPVC(pvcName, pvName, size, namespace, sc, isBlock) _, err = c.CoreV1().PersistentVolumeClaims(pvc.Namespace).Create(context.TODO(), pvc, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("PVC Create API error: %w", err) } // bind pvc to app app, err := loadApp(appPath) if err != nil { return err } app.Labels = make(map[string]string) app.Labels[appKey] = appLabel appOpt := metav1.ListOptions{ LabelSelector: fmt.Sprintf("%s=%s", appKey, appLabel), } app.Namespace = namespace app.Spec.Volumes[0].PersistentVolumeClaim.ClaimName = pvcName if checkImgFeat { err = createAppErr(f.ClientSet, app, deployTimeout, "missing required parameter imageFeatures") } else { err = createApp(f.ClientSet, app, deployTimeout) } if err != nil { return err } err = deletePod(app.Name, app.Namespace, f.ClientSet, deployTimeout) if err != nil { return err } // resize image only if the image is already mounted and formatted if !checkImgFeat { err = validateRBDStaticResize(f, app, &appOpt, pvc, rbdImageName) if err != nil { return err } } err = c.CoreV1().PersistentVolumeClaims(pvc.Namespace).Delete(context.TODO(), pvc.Name, metav1.DeleteOptions{}) if err != nil { return fmt.Errorf("failed to delete pvc: %w", err) } err = c.CoreV1().PersistentVolumes().Delete(context.TODO(), pv.Name, metav1.DeleteOptions{}) if err != nil { return fmt.Errorf("failed to delete pv: %w", err) } cmd = fmt.Sprintf("rbd rm %s %s", rbdImageName, rbdOptions(defaultRBDPool)) _, _, err = execCommandInToolBoxPod(f, cmd, rookNamespace) return err } func validateRBDStaticMigrationPVC(f *framework.Framework, appPath, scName string, isBlock bool) error { opt := make(map[string]string) var ( rbdImageName = "kubernetes-dynamic-pvc-e0b45b52-7e09-47d3-8f1b-806995fa4412" pvName = "pv-name" pvcName = "pvc-name" namespace = f.UniqueName sc = scName provisionerAnnKey = "pv.kubernetes.io/provisioned-by" provisionerAnnValue = "rbd.csi.ceph.com" ) c := f.ClientSet PVAnnMap := make(map[string]string) PVAnnMap[provisionerAnnKey] = provisionerAnnValue mons, err := getMons(rookNamespace, c) if err != nil { return fmt.Errorf("failed to get mons: %w", err) } mon := strings.Join(mons, ",") size := staticPVSize // create rbd image cmd := fmt.Sprintf( "rbd create %s --size=%s --image-feature=layering %s", rbdImageName, staticPVSize, rbdOptions(defaultRBDPool)) _, stdErr, err := execCommandInToolBoxPod(f, cmd, rookNamespace) if err != nil { return err } if stdErr != "" { return fmt.Errorf("failed to create rbd image %s", stdErr) } opt["migration"] = "true" opt["clusterID"] = getMonsHash(mon) opt["imageFeatures"] = staticPVImageFeature opt["pool"] = defaultRBDPool opt["staticVolume"] = strconv.FormatBool(true) opt["imageName"] = rbdImageName // Make volumeID similar to the migration volumeID volID := composeIntreeMigVolID(mon, rbdImageName) pv := getStaticPV( pvName, volID, size, rbdNodePluginSecretName, cephCSINamespace, sc, provisionerAnnValue, isBlock, opt, PVAnnMap, deletePolicy) _, err = c.CoreV1().PersistentVolumes().Create(context.TODO(), pv, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("PV Create API error: %w", err) } pvc := getStaticPVC(pvcName, pvName, size, namespace, sc, isBlock) _, err = c.CoreV1().PersistentVolumeClaims(pvc.Namespace).Create(context.TODO(), pvc, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("PVC Create API error: %w", err) } // bind pvc to app app, err := loadApp(appPath) if err != nil { return err } app.Namespace = namespace app.Spec.Volumes[0].PersistentVolumeClaim.ClaimName = pvcName err = createApp(f.ClientSet, app, deployTimeout) if err != nil { return err } err = deletePVCAndApp("", f, pvc, app) if err != nil { return fmt.Errorf("failed to delete PVC and application: %w", err) } return err } //nolint:gocyclo,cyclop // reduce complexity func validateCephFsStaticPV(f *framework.Framework, appPath, scPath string) error { opt := make(map[string]string) var ( cephFsVolName = "testSubVol" groupName = "testGroup" pvName = "pv-name" pvcName = "pvc-name" namespace = f.UniqueName // minikube creates default storage class in cluster, we need to set dummy // storageclass on PV and PVC to avoid storageclass name mismatch sc = "storage-class" secretName = "cephfs-static-pv-sc" // #nosec ) c := f.ClientSet listOpt := metav1.ListOptions{ LabelSelector: "app=rook-ceph-tools", } fsID, err := getClusterID(f) if err != nil { return fmt.Errorf("failed to get clusterID: %w", err) } // 4GiB in bytes size := "4294967296" // create subvolumegroup, command will work even if group is already present. cmd := fmt.Sprintf("ceph fs subvolumegroup create %s %s", fileSystemName, groupName) _, e, err := execCommandInPod(f, cmd, rookNamespace, &listOpt) if err != nil { return err } if e != "" { return fmt.Errorf("failed to create subvolumegroup: %s", e) } // create subvolume cmd = fmt.Sprintf("ceph fs subvolume create %s %s %s --size %s", fileSystemName, cephFsVolName, groupName, size) _, e, err = execCommandInPod(f, cmd, rookNamespace, &listOpt) if err != nil { return err } if e != "" { return fmt.Errorf("failed to create subvolume: %s", e) } // get rootpath cmd = fmt.Sprintf("ceph fs subvolume getpath %s %s %s", fileSystemName, cephFsVolName, groupName) rootPath, e, err := execCommandInPod(f, cmd, rookNamespace, &listOpt) if err != nil { return err } if e != "" { return fmt.Errorf("failed to get rootpath %s", e) } // remove new line present in rootPath rootPath = strings.Trim(rootPath, "\n") // create secret secret, err := getSecret(scPath) if err != nil { return err } adminKey, e, err := execCommandInPod(f, "ceph auth get-key client.admin", rookNamespace, &listOpt) if err != nil { return err } if e != "" { return fmt.Errorf("failed to get adminKey %s", e) } secret.StringData["userID"] = adminUser secret.StringData["userKey"] = adminKey secret.Name = secretName secret.Namespace = cephCSINamespace _, err = c.CoreV1().Secrets(cephCSINamespace).Create(context.TODO(), &secret, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("failed to create secret: %w", err) } opt["clusterID"] = fsID opt["fsName"] = fileSystemName opt["staticVolume"] = strconv.FormatBool(true) opt["rootPath"] = rootPath pv := getStaticPV( pvName, pvName, staticPVSize, secretName, cephCSINamespace, sc, "cephfs.csi.ceph.com", false, opt, nil, retainPolicy) _, err = c.CoreV1().PersistentVolumes().Create(context.TODO(), pv, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("failed to create PV: %w", err) } pvc := getStaticPVC(pvcName, pvName, size, namespace, sc, false) _, err = c.CoreV1().PersistentVolumeClaims(pvc.Namespace).Create(context.TODO(), pvc, metav1.CreateOptions{}) if err != nil { return fmt.Errorf("failed to create PVC: %w", err) } // bind pvc to app app, err := loadApp(appPath) if err != nil { return fmt.Errorf("failed to load app: %w", err) } app.Namespace = namespace app.Spec.Volumes[0].PersistentVolumeClaim.ClaimName = pvcName err = createApp(f.ClientSet, app, deployTimeout) if err != nil { return fmt.Errorf("failed to create pod: %w", err) } err = deletePod(app.Name, namespace, f.ClientSet, deployTimeout) if err != nil { return fmt.Errorf("failed to delete pod: %w", err) } err = c.CoreV1().PersistentVolumeClaims(pvc.Namespace).Delete(context.TODO(), pvc.Name, metav1.DeleteOptions{}) if err != nil { return fmt.Errorf("failed to delete pvc: %w", err) } err = c.CoreV1().PersistentVolumes().Delete(context.TODO(), pv.Name, metav1.DeleteOptions{}) if err != nil { return fmt.Errorf("failed to delete pv: %w", err) } err = c.CoreV1().Secrets(cephCSINamespace).Delete(context.TODO(), secret.Name, metav1.DeleteOptions{}) if err != nil { return fmt.Errorf("failed to delete secret: %w", err) } // delete subvolume cmd = fmt.Sprintf("ceph fs subvolume rm %s %s %s", fileSystemName, cephFsVolName, groupName) _, e, err = execCommandInPod(f, cmd, rookNamespace, &listOpt) if err != nil { return err } if e != "" { return fmt.Errorf("failed to remove sub-volume %s", e) } // delete subvolume group cmd = fmt.Sprintf("ceph fs subvolumegroup rm %s %s", fileSystemName, groupName) _, e, err = execCommandInPod(f, cmd, rookNamespace, &listOpt) if err != nil { return err } if e != "" { return fmt.Errorf("failed to remove subvolume group %s", e) } return nil } func validateRBDStaticResize( f *framework.Framework, app *v1.Pod, appOpt *metav1.ListOptions, pvc *v1.PersistentVolumeClaim, rbdImageName string, ) error { // resize rbd image size := staticPVNewSize cmd := fmt.Sprintf( "rbd resize %s --size=%s %s", rbdImageName, size, rbdOptions(defaultRBDPool)) _, _, err := execCommandInToolBoxPod(f, cmd, rookNamespace) if err != nil { return err } err = createApp(f.ClientSet, app, deployTimeout) if err != nil { return err } // check size for the filesystem type PVC if *pvc.Spec.VolumeMode == v1.PersistentVolumeFilesystem { err = checkDirSize(app, f, appOpt, size) if err != nil { return err } } return deletePod(app.Name, app.Namespace, f.ClientSet, deployTimeout) }