mirror of
https://github.com/ceph/ceph-csi.git
synced 2024-12-25 06:20:24 +00:00
b3a4f510e6
Take operation locks on the resources before operating on the resouces. This allows us to do parallel operations for some RPC calls such as Clone and Restore of PVC. This operations will only be blocked if the image is expanding or Snapshot and RBD image is getting deleted. Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
180 lines
6.0 KiB
Go
180 lines
6.0 KiB
Go
/*
|
|
Copyright 2018 The Ceph-CSI Authors.
|
|
|
|
Licensed under the Apache License, Version 2.0 (the "License");
|
|
you may not use this file except in compliance with the License.
|
|
You may obtain a copy of the License at
|
|
|
|
http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
Unless required by applicable law or agreed to in writing, software
|
|
distributed under the License is distributed on an "AS IS" BASIS,
|
|
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
See the License for the specific language governing permissions and
|
|
limitations under the License.
|
|
*/
|
|
|
|
package rbd
|
|
|
|
import (
|
|
csicommon "github.com/ceph/ceph-csi/internal/csi-common"
|
|
"github.com/ceph/ceph-csi/internal/journal"
|
|
"github.com/ceph/ceph-csi/internal/util"
|
|
|
|
"github.com/container-storage-interface/spec/lib/go/csi"
|
|
klog "k8s.io/klog/v2"
|
|
"k8s.io/utils/mount"
|
|
)
|
|
|
|
const (
|
|
// volIDVersion is the version number of volume ID encoding scheme
|
|
volIDVersion uint16 = 1
|
|
|
|
// csiConfigFile is the location of the CSI config file
|
|
csiConfigFile = "/etc/ceph-csi-config/config.json"
|
|
)
|
|
|
|
// Driver contains the default identity,node and controller struct.
|
|
type Driver struct {
|
|
cd *csicommon.CSIDriver
|
|
|
|
ids *IdentityServer
|
|
ns *NodeServer
|
|
cs *ControllerServer
|
|
}
|
|
|
|
var (
|
|
|
|
// CSIInstanceID is the instance ID that is unique to an instance of CSI, used when sharing
|
|
// ceph clusters across CSI instances, to differentiate omap names per CSI instance
|
|
CSIInstanceID = "default"
|
|
|
|
// volJournal and snapJournal are used to maintain RADOS based journals for CO generated
|
|
// VolumeName to backing RBD images
|
|
volJournal *journal.Config
|
|
snapJournal *journal.Config
|
|
// rbdHardMaxCloneDepth is the hard limit for maximum number of nested volume clones that are taken before a flatten occurs
|
|
rbdHardMaxCloneDepth uint
|
|
|
|
// rbdSoftMaxCloneDepth is the soft limit for maximum number of nested volume clones that are taken before a flatten occurs
|
|
rbdSoftMaxCloneDepth uint
|
|
maxSnapshotsOnImage uint
|
|
skipForceFlatten bool
|
|
)
|
|
|
|
// NewDriver returns new rbd driver.
|
|
func NewDriver() *Driver {
|
|
return &Driver{}
|
|
}
|
|
|
|
// NewIdentityServer initialize a identity server for rbd CSI driver.
|
|
func NewIdentityServer(d *csicommon.CSIDriver) *IdentityServer {
|
|
return &IdentityServer{
|
|
DefaultIdentityServer: csicommon.NewDefaultIdentityServer(d),
|
|
}
|
|
}
|
|
|
|
// NewControllerServer initialize a controller server for rbd CSI driver.
|
|
func NewControllerServer(d *csicommon.CSIDriver) *ControllerServer {
|
|
return &ControllerServer{
|
|
DefaultControllerServer: csicommon.NewDefaultControllerServer(d),
|
|
VolumeLocks: util.NewVolumeLocks(),
|
|
SnapshotLocks: util.NewVolumeLocks(),
|
|
OperationLocks: util.NewOperationLock(),
|
|
}
|
|
}
|
|
|
|
// NewNodeServer initialize a node server for rbd CSI driver.
|
|
func NewNodeServer(d *csicommon.CSIDriver, t string, topology map[string]string) (*NodeServer, error) {
|
|
mounter := mount.New("")
|
|
return &NodeServer{
|
|
DefaultNodeServer: csicommon.NewDefaultNodeServer(d, t, topology),
|
|
mounter: mounter,
|
|
VolumeLocks: util.NewVolumeLocks(),
|
|
}, nil
|
|
}
|
|
|
|
// Run start a non-blocking grpc controller,node and identityserver for
|
|
// rbd CSI driver which can serve multiple parallel requests.
|
|
func (r *Driver) Run(conf *util.Config) {
|
|
var err error
|
|
var topology map[string]string
|
|
|
|
// Create ceph.conf for use with CLI commands
|
|
if err = util.WriteCephConfig(); err != nil {
|
|
klog.Fatalf("failed to write ceph configuration file (%v)", err)
|
|
}
|
|
|
|
// Use passed in instance ID, if provided for omap suffix naming
|
|
if conf.InstanceID != "" {
|
|
CSIInstanceID = conf.InstanceID
|
|
}
|
|
|
|
// update clone soft and hard limit
|
|
rbdHardMaxCloneDepth = conf.RbdHardMaxCloneDepth
|
|
rbdSoftMaxCloneDepth = conf.RbdSoftMaxCloneDepth
|
|
skipForceFlatten = conf.SkipForceFlatten
|
|
maxSnapshotsOnImage = conf.MaxSnapshotsOnImage
|
|
// Create instances of the volume and snapshot journal
|
|
volJournal = journal.NewCSIVolumeJournal(CSIInstanceID)
|
|
snapJournal = journal.NewCSISnapshotJournal(CSIInstanceID)
|
|
|
|
// Initialize default library driver
|
|
r.cd = csicommon.NewCSIDriver(conf.DriverName, util.DriverVersion, conf.NodeID)
|
|
if r.cd == nil {
|
|
klog.Fatalln("Failed to initialize CSI Driver.")
|
|
}
|
|
if conf.IsControllerServer || !conf.IsNodeServer {
|
|
r.cd.AddControllerServiceCapabilities([]csi.ControllerServiceCapability_RPC_Type{
|
|
csi.ControllerServiceCapability_RPC_CREATE_DELETE_VOLUME,
|
|
csi.ControllerServiceCapability_RPC_CREATE_DELETE_SNAPSHOT,
|
|
csi.ControllerServiceCapability_RPC_CLONE_VOLUME,
|
|
csi.ControllerServiceCapability_RPC_EXPAND_VOLUME,
|
|
})
|
|
// We only support the multi-writer option when using block, but it's a supported capability for the plugin in general
|
|
// In addition, we want to add the remaining modes like MULTI_NODE_READER_ONLY,
|
|
// MULTI_NODE_SINGLE_WRITER etc, but need to do some verification of RO modes first
|
|
// will work those as follow up features
|
|
r.cd.AddVolumeCapabilityAccessModes(
|
|
[]csi.VolumeCapability_AccessMode_Mode{csi.VolumeCapability_AccessMode_SINGLE_NODE_WRITER,
|
|
csi.VolumeCapability_AccessMode_MULTI_NODE_MULTI_WRITER})
|
|
}
|
|
|
|
// Create GRPC servers
|
|
r.ids = NewIdentityServer(r.cd)
|
|
|
|
if conf.IsNodeServer {
|
|
topology, err = util.GetTopologyFromDomainLabels(conf.DomainLabels, conf.NodeID, conf.DriverName)
|
|
if err != nil {
|
|
klog.Fatalln(err)
|
|
}
|
|
r.ns, err = NewNodeServer(r.cd, conf.Vtype, topology)
|
|
if err != nil {
|
|
klog.Fatalf("failed to start node server, err %v\n", err)
|
|
}
|
|
}
|
|
|
|
if conf.IsControllerServer {
|
|
r.cs = NewControllerServer(r.cd)
|
|
}
|
|
if !conf.IsControllerServer && !conf.IsNodeServer {
|
|
topology, err = util.GetTopologyFromDomainLabels(conf.DomainLabels, conf.NodeID, conf.DriverName)
|
|
if err != nil {
|
|
klog.Fatalln(err)
|
|
}
|
|
r.ns, err = NewNodeServer(r.cd, conf.Vtype, topology)
|
|
if err != nil {
|
|
klog.Fatalf("failed to start node server, err %v\n", err)
|
|
}
|
|
r.cs = NewControllerServer(r.cd)
|
|
}
|
|
|
|
s := csicommon.NewNonBlockingGRPCServer()
|
|
s.Start(conf.Endpoint, conf.HistogramOption, r.ids, r.cs, r.ns, conf.EnableGRPCMetrics)
|
|
if conf.EnableGRPCMetrics {
|
|
klog.Warning("EnableGRPCMetrics is deprecated")
|
|
go util.StartMetricsServer(conf)
|
|
}
|
|
s.Wait()
|
|
}
|