mirror of
https://github.com/ceph/ceph-csi.git
synced 2024-12-25 14:30:22 +00:00
e768c0dfc0
replace klog with util logger in nodeserver.go Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
895 lines
30 KiB
Go
895 lines
30 KiB
Go
/*
|
|
Copyright 2018 The Ceph-CSI Authors.
|
|
|
|
Licensed under the Apache License, Version 2.0 (the "License");
|
|
you may not use this file except in compliance with the License.
|
|
You may obtain a copy of the License at
|
|
|
|
http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
Unless required by applicable law or agreed to in writing, software
|
|
distributed under the License is distributed on an "AS IS" BASIS,
|
|
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
See the License for the specific language governing permissions and
|
|
limitations under the License.
|
|
*/
|
|
|
|
package rbd
|
|
|
|
import (
|
|
"context"
|
|
"errors"
|
|
"fmt"
|
|
"os"
|
|
"strconv"
|
|
"strings"
|
|
|
|
csicommon "github.com/ceph/ceph-csi/internal/csi-common"
|
|
"github.com/ceph/ceph-csi/internal/journal"
|
|
"github.com/ceph/ceph-csi/internal/util"
|
|
|
|
librbd "github.com/ceph/go-ceph/rbd"
|
|
"github.com/container-storage-interface/spec/lib/go/csi"
|
|
"google.golang.org/grpc/codes"
|
|
"google.golang.org/grpc/status"
|
|
"k8s.io/kubernetes/pkg/util/resizefs"
|
|
utilexec "k8s.io/utils/exec"
|
|
"k8s.io/utils/mount"
|
|
)
|
|
|
|
// NodeServer struct of ceph rbd driver with supported methods of CSI
|
|
// node server spec.
|
|
type NodeServer struct {
|
|
*csicommon.DefaultNodeServer
|
|
mounter mount.Interface
|
|
// A map storing all volumes with ongoing operations so that additional operations
|
|
// for that same volume (as defined by VolumeID) return an Aborted error
|
|
VolumeLocks *util.VolumeLocks
|
|
}
|
|
|
|
// stageTransaction struct represents the state a transaction was when it either completed
|
|
// or failed
|
|
// this transaction state can be used to rollback the transaction.
|
|
type stageTransaction struct {
|
|
// isStagePathCreated represents whether the mount path to stage the volume on was created or not
|
|
isStagePathCreated bool
|
|
// isMounted represents if the volume was mounted or not
|
|
isMounted bool
|
|
// isEncrypted represents if the volume was encrypted or not
|
|
isEncrypted bool
|
|
// devicePath represents the path where rbd device is mapped
|
|
devicePath string
|
|
}
|
|
|
|
const (
|
|
// values for xfsHasReflink
|
|
xfsReflinkUnset int = iota
|
|
xfsReflinkNoSupport
|
|
xfsReflinkSupport
|
|
)
|
|
|
|
var (
|
|
kernelRelease = ""
|
|
// deepFlattenSupport holds the list of kernel which support mapping rbd
|
|
// image with deep-flatten image feature
|
|
// nolint:gomnd // numbers specify Kernel versions.
|
|
deepFlattenSupport = []util.KernelVersion{
|
|
{
|
|
Version: 5,
|
|
PatchLevel: 1,
|
|
SubLevel: 0,
|
|
ExtraVersion: 0,
|
|
Distribution: "",
|
|
Backport: false,
|
|
}, // standard 5.1+ versions
|
|
{
|
|
Version: 4,
|
|
PatchLevel: 18,
|
|
SubLevel: 0,
|
|
ExtraVersion: 193,
|
|
Distribution: ".el8",
|
|
Backport: true,
|
|
}, // RHEL 8.2
|
|
}
|
|
|
|
// xfsHasReflink is set by xfsSupportsReflink(), use the function when
|
|
// checking the support for reflink
|
|
xfsHasReflink = xfsReflinkUnset
|
|
)
|
|
|
|
// NodeStageVolume mounts the volume to a staging path on the node.
|
|
// Implementation notes:
|
|
// - stagingTargetPath is the directory passed in the request where the volume needs to be staged
|
|
// - We stage the volume into a directory, named after the VolumeID inside stagingTargetPath if
|
|
// it is a file system
|
|
// - We stage the volume into a file, named after the VolumeID inside stagingTargetPath if it is
|
|
// a block volume
|
|
// - Order of operation execution: (useful for defer stacking and when Unstaging to ensure steps
|
|
// are done in reverse, this is done in undoStagingTransaction)
|
|
// - Stash image metadata under staging path
|
|
// - Map the image (creates a device)
|
|
// - Create the staging file/directory under staging path
|
|
// - Stage the device (mount the device mapped for image)
|
|
// TODO: make this function less complex
|
|
// nolint:gocyclo // complexity needs to be reduced.
|
|
func (ns *NodeServer) NodeStageVolume(ctx context.Context, req *csi.NodeStageVolumeRequest) (*csi.NodeStageVolumeResponse, error) {
|
|
if err := util.ValidateNodeStageVolumeRequest(req); err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
|
disableInUseChecks := false
|
|
// MULTI_NODE_MULTI_WRITER is supported by default for Block access type volumes
|
|
if req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_MULTI_NODE_MULTI_WRITER {
|
|
if !isBlock {
|
|
util.WarningLog(ctx, "MULTI_NODE_MULTI_WRITER currently only supported with volumes of access type `block`, invalid AccessMode for volume: %v", req.GetVolumeId())
|
|
return nil, status.Error(codes.InvalidArgument, "rbd: RWX access mode request is only valid for volumes with access type `block`")
|
|
}
|
|
|
|
disableInUseChecks = true
|
|
}
|
|
|
|
volID := req.GetVolumeId()
|
|
|
|
cr, err := util.NewUserCredentials(req.GetSecrets())
|
|
if err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
defer cr.DeleteCredentials()
|
|
|
|
if acquired := ns.VolumeLocks.TryAcquire(volID); !acquired {
|
|
util.ErrorLog(ctx, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
return nil, status.Errorf(codes.Aborted, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
}
|
|
defer ns.VolumeLocks.Release(volID)
|
|
|
|
stagingParentPath := req.GetStagingTargetPath()
|
|
stagingTargetPath := stagingParentPath + "/" + volID
|
|
|
|
// check is it a static volume
|
|
staticVol := false
|
|
val, ok := req.GetVolumeContext()["staticVolume"]
|
|
if ok {
|
|
if staticVol, err = strconv.ParseBool(val); err != nil {
|
|
return nil, status.Error(codes.InvalidArgument, err.Error())
|
|
}
|
|
}
|
|
|
|
var isNotMnt bool
|
|
// check if stagingPath is already mounted
|
|
isNotMnt, err = mount.IsNotMountPoint(ns.mounter, stagingTargetPath)
|
|
if err != nil && !os.IsNotExist(err) {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
if !isNotMnt {
|
|
util.DebugLog(ctx, "rbd: volume %s is already mounted to %s, skipping", volID, stagingTargetPath)
|
|
return &csi.NodeStageVolumeResponse{}, nil
|
|
}
|
|
|
|
volOptions, err := genVolFromVolumeOptions(ctx, req.GetVolumeContext(), req.GetSecrets(), disableInUseChecks)
|
|
if err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
// get rbd image name from the volume journal
|
|
// for static volumes, the image name is actually the volume ID itself
|
|
switch {
|
|
case staticVol:
|
|
volOptions.RbdImageName = volID
|
|
default:
|
|
var vi util.CSIIdentifier
|
|
var imageAttributes *journal.ImageAttributes
|
|
err = vi.DecomposeCSIID(volID)
|
|
if err != nil {
|
|
err = fmt.Errorf("error decoding volume ID (%s) (%s)", err, volID)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
j, err2 := volJournal.Connect(volOptions.Monitors, volOptions.RadosNamespace, cr)
|
|
if err2 != nil {
|
|
util.ErrorLog(ctx, "failed to establish cluster connection: %v", err2)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
defer j.Destroy()
|
|
|
|
imageAttributes, err = j.GetImageAttributes(
|
|
ctx, volOptions.Pool, vi.ObjectUUID, false)
|
|
if err != nil {
|
|
err = fmt.Errorf("error fetching image attributes for volume ID (%s) (%s)", err, volID)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
volOptions.RbdImageName = imageAttributes.ImageName
|
|
}
|
|
|
|
volOptions.VolID = volID
|
|
transaction := stageTransaction{}
|
|
|
|
// Stash image details prior to mapping the image (useful during Unstage as it has no
|
|
// voloptions passed to the RPC as per the CSI spec)
|
|
err = stashRBDImageMetadata(volOptions, stagingParentPath)
|
|
if err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
defer func() {
|
|
if err != nil {
|
|
ns.undoStagingTransaction(ctx, req, transaction)
|
|
}
|
|
}()
|
|
|
|
// perform the actual staging and if this fails, have undoStagingTransaction
|
|
// cleans up for us
|
|
transaction, err = ns.stageTransaction(ctx, req, volOptions, staticVol)
|
|
if err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
util.DebugLog(ctx, "rbd: successfully mounted volume %s to stagingTargetPath %s", req.GetVolumeId(), stagingTargetPath)
|
|
|
|
return &csi.NodeStageVolumeResponse{}, nil
|
|
}
|
|
|
|
func (ns *NodeServer) stageTransaction(ctx context.Context, req *csi.NodeStageVolumeRequest, volOptions *rbdVolume, staticVol bool) (stageTransaction, error) {
|
|
transaction := stageTransaction{}
|
|
|
|
var err error
|
|
var readOnly bool
|
|
var feature bool
|
|
|
|
var cr *util.Credentials
|
|
cr, err = util.NewUserCredentials(req.GetSecrets())
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
defer cr.DeleteCredentials()
|
|
|
|
err = volOptions.Connect(cr)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to connect to volume %v: %v", volOptions.RbdImageName, err)
|
|
return transaction, err
|
|
}
|
|
defer volOptions.Destroy()
|
|
|
|
// Allow image to be mounted on multiple nodes if it is ROX
|
|
if req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_MULTI_NODE_READER_ONLY {
|
|
util.ExtendedLog(ctx, "setting disableInUseChecks on rbd volume to: %v", req.GetVolumeId)
|
|
volOptions.DisableInUseChecks = true
|
|
volOptions.readOnly = true
|
|
}
|
|
|
|
if kernelRelease == "" {
|
|
// fetch the current running kernel info
|
|
kernelRelease, err = util.GetKernelVersion()
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
}
|
|
if !util.CheckKernelSupport(kernelRelease, deepFlattenSupport) {
|
|
if !skipForceFlatten {
|
|
feature, err = volOptions.checkImageChainHasFeature(ctx, librbd.FeatureDeepFlatten)
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
if feature {
|
|
err = volOptions.flattenRbdImage(ctx, cr, true, rbdHardMaxCloneDepth, rbdSoftMaxCloneDepth)
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
}
|
|
}
|
|
}
|
|
// Mapping RBD image
|
|
var devicePath string
|
|
devicePath, err = attachRBDImage(ctx, volOptions, cr)
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
transaction.devicePath = devicePath
|
|
util.DebugLog(ctx, "rbd image: %s/%s was successfully mapped at %s\n",
|
|
req.GetVolumeId(), volOptions.Pool, devicePath)
|
|
|
|
if volOptions.Encrypted {
|
|
devicePath, err = ns.processEncryptedDevice(ctx, volOptions, devicePath)
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
transaction.isEncrypted = true
|
|
}
|
|
|
|
stagingTargetPath := getStagingTargetPath(req)
|
|
|
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
|
err = ns.createStageMountPoint(ctx, stagingTargetPath, isBlock)
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
|
|
transaction.isStagePathCreated = true
|
|
|
|
// nodeStage Path
|
|
readOnly, err = ns.mountVolumeToStagePath(ctx, req, staticVol, stagingTargetPath, devicePath)
|
|
if err != nil {
|
|
return transaction, err
|
|
}
|
|
transaction.isMounted = true
|
|
|
|
if !readOnly {
|
|
// #nosec - allow anyone to write inside the target path
|
|
err = os.Chmod(stagingTargetPath, 0777)
|
|
}
|
|
return transaction, err
|
|
}
|
|
|
|
func (ns *NodeServer) undoStagingTransaction(ctx context.Context, req *csi.NodeStageVolumeRequest, transaction stageTransaction) {
|
|
var err error
|
|
|
|
stagingTargetPath := getStagingTargetPath(req)
|
|
if transaction.isMounted {
|
|
err = ns.mounter.Unmount(stagingTargetPath)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to unmount stagingtargetPath: %s with error: %v", stagingTargetPath, err)
|
|
return
|
|
}
|
|
}
|
|
|
|
// remove the file/directory created on staging path
|
|
if transaction.isStagePathCreated {
|
|
err = os.Remove(stagingTargetPath)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to remove stagingtargetPath: %s with error: %v", stagingTargetPath, err)
|
|
// continue on failure to unmap the image, as leaving stale images causes more issues than a stale file/directory
|
|
}
|
|
}
|
|
|
|
volID := req.GetVolumeId()
|
|
|
|
// Unmapping rbd device
|
|
if transaction.devicePath != "" {
|
|
err = detachRBDDevice(ctx, transaction.devicePath, volID, transaction.isEncrypted)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to unmap rbd device: %s for volume %s with error: %v", transaction.devicePath, volID, err)
|
|
// continue on failure to delete the stash file, as kubernetes will fail to delete the staging path otherwise
|
|
}
|
|
}
|
|
|
|
// Cleanup the stashed image metadata
|
|
if err = cleanupRBDImageMetadataStash(req.GetStagingTargetPath()); err != nil {
|
|
util.ErrorLog(ctx, "failed to cleanup image metadata stash (%v)", err)
|
|
return
|
|
}
|
|
}
|
|
|
|
func (ns *NodeServer) createStageMountPoint(ctx context.Context, mountPath string, isBlock bool) error {
|
|
if isBlock {
|
|
pathFile, err := os.OpenFile(mountPath, os.O_CREATE|os.O_RDWR, 0600)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to create mountPath:%s with error: %v", mountPath, err)
|
|
return status.Error(codes.Internal, err.Error())
|
|
}
|
|
if err = pathFile.Close(); err != nil {
|
|
util.ErrorLog(ctx, "failed to close mountPath:%s with error: %v", mountPath, err)
|
|
return status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
err := os.Mkdir(mountPath, 0750)
|
|
if err != nil {
|
|
if !os.IsExist(err) {
|
|
util.ErrorLog(ctx, "failed to create mountPath:%s with error: %v", mountPath, err)
|
|
return status.Error(codes.Internal, err.Error())
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
// NodePublishVolume mounts the volume mounted to the device path to the target
|
|
// path.
|
|
func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublishVolumeRequest) (*csi.NodePublishVolumeResponse, error) {
|
|
err := util.ValidateNodePublishVolumeRequest(req)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
targetPath := req.GetTargetPath()
|
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
|
stagingPath := req.GetStagingTargetPath()
|
|
volID := req.GetVolumeId()
|
|
stagingPath += "/" + volID
|
|
|
|
if acquired := ns.VolumeLocks.TryAcquire(volID); !acquired {
|
|
util.ErrorLog(ctx, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
return nil, status.Errorf(codes.Aborted, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
}
|
|
defer ns.VolumeLocks.Release(volID)
|
|
|
|
// Check if that target path exists properly
|
|
notMnt, err := ns.createTargetMountPath(ctx, targetPath, isBlock)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
if !notMnt {
|
|
return &csi.NodePublishVolumeResponse{}, nil
|
|
}
|
|
|
|
// Publish Path
|
|
err = ns.mountVolume(ctx, stagingPath, req)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
util.DebugLog(ctx, "rbd: successfully mounted stagingPath %s to targetPath %s", stagingPath, targetPath)
|
|
return &csi.NodePublishVolumeResponse{}, nil
|
|
}
|
|
|
|
func (ns *NodeServer) mountVolumeToStagePath(ctx context.Context, req *csi.NodeStageVolumeRequest, staticVol bool, stagingPath, devicePath string) (bool, error) {
|
|
readOnly := false
|
|
fsType := req.GetVolumeCapability().GetMount().GetFsType()
|
|
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
|
|
// rbd images are thin-provisioned and return zeros for unwritten areas. A freshly created
|
|
// image will not benefit from discard and we also want to avoid as much unnecessary zeroing
|
|
// as possible. Open-code mkfs here because FormatAndMount() doesn't accept custom mkfs
|
|
// options.
|
|
//
|
|
// Note that "freshly" is very important here. While discard is more of a nice to have,
|
|
// lazy_journal_init=1 is plain unsafe if the image has been written to before and hasn't
|
|
// been zeroed afterwards (unlike the name suggests, it leaves the journal completely
|
|
// uninitialized and carries a risk until the journal is overwritten and wraps around for
|
|
// the first time).
|
|
existingFormat, err := diskMounter.GetDiskFormat(devicePath)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to get disk format for path %s, error: %v", devicePath, err)
|
|
return readOnly, err
|
|
}
|
|
|
|
opt := []string{"_netdev"}
|
|
opt = csicommon.ConstructMountOptions(opt, req.GetVolumeCapability())
|
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
|
rOnly := "ro"
|
|
|
|
if req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_MULTI_NODE_READER_ONLY ||
|
|
req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_SINGLE_NODE_READER_ONLY {
|
|
if !csicommon.MountOptionContains(opt, rOnly) {
|
|
opt = append(opt, rOnly)
|
|
}
|
|
}
|
|
if csicommon.MountOptionContains(opt, rOnly) {
|
|
readOnly = true
|
|
}
|
|
|
|
if fsType == "xfs" {
|
|
opt = append(opt, "nouuid")
|
|
}
|
|
|
|
if existingFormat == "" && !staticVol && !readOnly {
|
|
args := []string{}
|
|
if fsType == "ext4" {
|
|
args = []string{"-m0", "-Enodiscard,lazy_itable_init=1,lazy_journal_init=1", devicePath}
|
|
} else if fsType == "xfs" {
|
|
args = []string{"-K", devicePath}
|
|
// always disable reflink
|
|
// TODO: make enabling an option, see ceph/ceph-csi#1256
|
|
if ns.xfsSupportsReflink() {
|
|
args = append(args, "-m", "reflink=0")
|
|
}
|
|
}
|
|
if len(args) > 0 {
|
|
cmdOut, cmdErr := diskMounter.Exec.Command("mkfs."+fsType, args...).CombinedOutput()
|
|
if cmdErr != nil {
|
|
util.ErrorLog(ctx, "failed to run mkfs error: %v, output: %v", cmdErr, string(cmdOut))
|
|
return readOnly, cmdErr
|
|
}
|
|
}
|
|
}
|
|
|
|
if isBlock {
|
|
opt = append(opt, "bind")
|
|
err = diskMounter.Mount(devicePath, stagingPath, fsType, opt)
|
|
} else {
|
|
err = diskMounter.FormatAndMount(devicePath, stagingPath, fsType, opt)
|
|
}
|
|
if err != nil {
|
|
util.ErrorLog(ctx,
|
|
"failed to mount device path (%s) to staging path (%s) for volume "+
|
|
"(%s) error: %s Check dmesg logs if required.",
|
|
devicePath,
|
|
stagingPath,
|
|
req.GetVolumeId(),
|
|
err)
|
|
}
|
|
return readOnly, err
|
|
}
|
|
|
|
func (ns *NodeServer) mountVolume(ctx context.Context, stagingPath string, req *csi.NodePublishVolumeRequest) error {
|
|
// Publish Path
|
|
fsType := req.GetVolumeCapability().GetMount().GetFsType()
|
|
readOnly := req.GetReadonly()
|
|
mountOptions := []string{"bind", "_netdev"}
|
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
|
targetPath := req.GetTargetPath()
|
|
|
|
mountOptions = csicommon.ConstructMountOptions(mountOptions, req.GetVolumeCapability())
|
|
|
|
util.DebugLog(ctx, "target %v\nisBlock %v\nfstype %v\nstagingPath %v\nreadonly %v\nmountflags %v\n",
|
|
targetPath, isBlock, fsType, stagingPath, readOnly, mountOptions)
|
|
|
|
if readOnly {
|
|
mountOptions = append(mountOptions, "ro")
|
|
}
|
|
if err := util.Mount(stagingPath, targetPath, fsType, mountOptions); err != nil {
|
|
return status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (ns *NodeServer) createTargetMountPath(ctx context.Context, mountPath string, isBlock bool) (bool, error) {
|
|
// Check if that mount path exists properly
|
|
notMnt, err := mount.IsNotMountPoint(ns.mounter, mountPath)
|
|
if err != nil {
|
|
if os.IsNotExist(err) {
|
|
if isBlock {
|
|
// #nosec
|
|
pathFile, e := os.OpenFile(mountPath, os.O_CREATE|os.O_RDWR, 0750)
|
|
if e != nil {
|
|
util.DebugLog(ctx, "Failed to create mountPath:%s with error: %v", mountPath, err)
|
|
return notMnt, status.Error(codes.Internal, e.Error())
|
|
}
|
|
if err = pathFile.Close(); err != nil {
|
|
util.DebugLog(ctx, "Failed to close mountPath:%s with error: %v", mountPath, err)
|
|
return notMnt, status.Error(codes.Internal, err.Error())
|
|
}
|
|
} else {
|
|
// Create a directory
|
|
if err = util.CreateMountPoint(mountPath); err != nil {
|
|
return notMnt, status.Error(codes.Internal, err.Error())
|
|
}
|
|
}
|
|
notMnt = true
|
|
} else {
|
|
return false, status.Error(codes.Internal, err.Error())
|
|
}
|
|
}
|
|
return notMnt, err
|
|
}
|
|
|
|
// NodeUnpublishVolume unmounts the volume from the target path.
|
|
func (ns *NodeServer) NodeUnpublishVolume(ctx context.Context, req *csi.NodeUnpublishVolumeRequest) (*csi.NodeUnpublishVolumeResponse, error) {
|
|
err := util.ValidateNodeUnpublishVolumeRequest(req)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
targetPath := req.GetTargetPath()
|
|
volID := req.GetVolumeId()
|
|
|
|
if acquired := ns.VolumeLocks.TryAcquire(volID); !acquired {
|
|
util.ErrorLog(ctx, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
return nil, status.Errorf(codes.Aborted, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
}
|
|
defer ns.VolumeLocks.Release(volID)
|
|
|
|
notMnt, err := mount.IsNotMountPoint(ns.mounter, targetPath)
|
|
if err != nil {
|
|
if os.IsNotExist(err) {
|
|
// targetPath has already been deleted
|
|
util.DebugLog(ctx, "targetPath: %s has already been deleted", targetPath)
|
|
return &csi.NodeUnpublishVolumeResponse{}, nil
|
|
}
|
|
return nil, status.Error(codes.NotFound, err.Error())
|
|
}
|
|
if notMnt {
|
|
if err = os.RemoveAll(targetPath); err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
return &csi.NodeUnpublishVolumeResponse{}, nil
|
|
}
|
|
|
|
if err = ns.mounter.Unmount(targetPath); err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
if err = os.RemoveAll(targetPath); err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
util.DebugLog(ctx, "rbd: successfully unbound volume %s from %s", req.GetVolumeId(), targetPath)
|
|
|
|
return &csi.NodeUnpublishVolumeResponse{}, nil
|
|
}
|
|
|
|
// getStagingTargetPath concats either NodeStageVolumeRequest's or
|
|
// NodeUnstageVolumeRequest's target path with the volumeID.
|
|
func getStagingTargetPath(req interface{}) string {
|
|
switch vr := req.(type) {
|
|
case *csi.NodeStageVolumeRequest:
|
|
return vr.GetStagingTargetPath() + "/" + vr.GetVolumeId()
|
|
case *csi.NodeUnstageVolumeRequest:
|
|
return vr.GetStagingTargetPath() + "/" + vr.GetVolumeId()
|
|
}
|
|
|
|
return ""
|
|
}
|
|
|
|
// NodeUnstageVolume unstages the volume from the staging path.
|
|
func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstageVolumeRequest) (*csi.NodeUnstageVolumeResponse, error) {
|
|
var err error
|
|
if err = util.ValidateNodeUnstageVolumeRequest(req); err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
volID := req.GetVolumeId()
|
|
|
|
if acquired := ns.VolumeLocks.TryAcquire(volID); !acquired {
|
|
util.ErrorLog(ctx, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
return nil, status.Errorf(codes.Aborted, util.VolumeOperationAlreadyExistsFmt, volID)
|
|
}
|
|
defer ns.VolumeLocks.Release(volID)
|
|
|
|
stagingParentPath := req.GetStagingTargetPath()
|
|
stagingTargetPath := getStagingTargetPath(req)
|
|
|
|
notMnt, err := mount.IsNotMountPoint(ns.mounter, stagingTargetPath)
|
|
if err != nil {
|
|
if !os.IsNotExist(err) {
|
|
return nil, status.Error(codes.NotFound, err.Error())
|
|
}
|
|
// Continue on ENOENT errors as we may still have the image mapped
|
|
notMnt = true
|
|
}
|
|
if !notMnt {
|
|
// Unmounting the image
|
|
err = ns.mounter.Unmount(stagingTargetPath)
|
|
if err != nil {
|
|
util.ExtendedLog(ctx, "failed to unmount targetPath: %s with error: %v", stagingTargetPath, err)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
}
|
|
|
|
if err = os.Remove(stagingTargetPath); err != nil {
|
|
// Any error is critical as Staging path is expected to be empty by Kubernetes, it otherwise
|
|
// keeps invoking Unstage. Hence any errors removing files within this path is a critical
|
|
// error
|
|
if !os.IsNotExist(err) {
|
|
util.ErrorLog(ctx, "failed to remove staging target path (%s): (%v)", stagingTargetPath, err)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
}
|
|
|
|
imgInfo, err := lookupRBDImageMetadataStash(stagingParentPath)
|
|
if err != nil {
|
|
util.UsefulLog(ctx, "failed to find image metadata: %v", err)
|
|
// It is an error if it was mounted, as we should have found the image metadata file with
|
|
// no errors
|
|
if !notMnt {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
// If not mounted, and error is anything other than metadata file missing, it is an error
|
|
if !errors.Is(err, ErrMissingStash) {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
// It was not mounted and image metadata is also missing, we are done as the last step in
|
|
// in the staging transaction is complete
|
|
return &csi.NodeUnstageVolumeResponse{}, nil
|
|
}
|
|
|
|
// Unmapping rbd device
|
|
imageSpec := imgInfo.String()
|
|
if err = detachRBDImageOrDeviceSpec(ctx, imageSpec, true, imgInfo.NbdAccess, imgInfo.Encrypted, req.GetVolumeId()); err != nil {
|
|
util.ErrorLog(ctx, "error unmapping volume (%s) from staging path (%s): (%v)", req.GetVolumeId(), stagingTargetPath, err)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
util.DebugLog(ctx, "successfully unmounted volume (%s) from staging path (%s)",
|
|
req.GetVolumeId(), stagingTargetPath)
|
|
|
|
if err = cleanupRBDImageMetadataStash(stagingParentPath); err != nil {
|
|
util.ErrorLog(ctx, "failed to cleanup image metadata stash (%v)", err)
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
return &csi.NodeUnstageVolumeResponse{}, nil
|
|
}
|
|
|
|
// NodeExpandVolume resizes rbd volumes.
|
|
func (ns *NodeServer) NodeExpandVolume(ctx context.Context, req *csi.NodeExpandVolumeRequest) (*csi.NodeExpandVolumeResponse, error) {
|
|
volumeID := req.GetVolumeId()
|
|
if volumeID == "" {
|
|
return nil, status.Error(codes.InvalidArgument, "volume ID must be provided")
|
|
}
|
|
volumePath := req.GetVolumePath()
|
|
if volumePath == "" {
|
|
return nil, status.Error(codes.InvalidArgument, "volume path must be provided")
|
|
}
|
|
|
|
if acquired := ns.VolumeLocks.TryAcquire(volumeID); !acquired {
|
|
util.ErrorLog(ctx, util.VolumeOperationAlreadyExistsFmt, volumeID)
|
|
return nil, status.Errorf(codes.Aborted, util.VolumeOperationAlreadyExistsFmt, volumeID)
|
|
}
|
|
defer ns.VolumeLocks.Release(volumeID)
|
|
|
|
devicePath, err := getDevicePath(ctx, volumePath)
|
|
if err != nil {
|
|
return nil, status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
|
|
// TODO check size and return success or error
|
|
volumePath += "/" + volumeID
|
|
resizer := resizefs.NewResizeFs(diskMounter)
|
|
ok, err := resizer.Resize(devicePath, volumePath)
|
|
if !ok {
|
|
return nil, fmt.Errorf("rbd: resize failed on path %s, error: %v", req.GetVolumePath(), err)
|
|
}
|
|
return &csi.NodeExpandVolumeResponse{}, nil
|
|
}
|
|
|
|
func getDevicePath(ctx context.Context, volumePath string) (string, error) {
|
|
imgInfo, err := lookupRBDImageMetadataStash(volumePath)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to find image metadata: %v", err)
|
|
}
|
|
device, found := findDeviceMappingImage(ctx, imgInfo.Pool, imgInfo.RadosNamespace, imgInfo.ImageName, imgInfo.NbdAccess)
|
|
if found {
|
|
return device, nil
|
|
}
|
|
return "", fmt.Errorf("failed to get device for stagingtarget path %v", volumePath)
|
|
}
|
|
|
|
// NodeGetCapabilities returns the supported capabilities of the node server.
|
|
func (ns *NodeServer) NodeGetCapabilities(ctx context.Context, req *csi.NodeGetCapabilitiesRequest) (*csi.NodeGetCapabilitiesResponse, error) {
|
|
return &csi.NodeGetCapabilitiesResponse{
|
|
Capabilities: []*csi.NodeServiceCapability{
|
|
{
|
|
Type: &csi.NodeServiceCapability_Rpc{
|
|
Rpc: &csi.NodeServiceCapability_RPC{
|
|
Type: csi.NodeServiceCapability_RPC_STAGE_UNSTAGE_VOLUME,
|
|
},
|
|
},
|
|
},
|
|
{
|
|
Type: &csi.NodeServiceCapability_Rpc{
|
|
Rpc: &csi.NodeServiceCapability_RPC{
|
|
Type: csi.NodeServiceCapability_RPC_GET_VOLUME_STATS,
|
|
},
|
|
},
|
|
},
|
|
{
|
|
Type: &csi.NodeServiceCapability_Rpc{
|
|
Rpc: &csi.NodeServiceCapability_RPC{
|
|
Type: csi.NodeServiceCapability_RPC_EXPAND_VOLUME,
|
|
},
|
|
},
|
|
},
|
|
},
|
|
}, nil
|
|
}
|
|
|
|
func (ns *NodeServer) processEncryptedDevice(ctx context.Context, volOptions *rbdVolume, devicePath string) (string, error) {
|
|
imageSpec := volOptions.String()
|
|
encrypted, err := volOptions.checkRbdImageEncrypted(ctx)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to get encryption status for rbd image %s: %v",
|
|
imageSpec, err)
|
|
return "", err
|
|
}
|
|
|
|
if encrypted == rbdImageRequiresEncryption {
|
|
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
|
|
// TODO: update this when adding support for static (pre-provisioned) PVs
|
|
var existingFormat string
|
|
existingFormat, err = diskMounter.GetDiskFormat(devicePath)
|
|
if err != nil {
|
|
return "", fmt.Errorf("failed to get disk format for path %s, error: %v", devicePath, err)
|
|
}
|
|
|
|
switch existingFormat {
|
|
case "":
|
|
err = encryptDevice(ctx, volOptions, devicePath)
|
|
if err != nil {
|
|
return "", fmt.Errorf("failed to encrypt rbd image %s: %v", imageSpec, err)
|
|
}
|
|
case "crypt":
|
|
util.WarningLog(ctx, "rbd image %s is encrypted, but encryption state was not updated",
|
|
imageSpec)
|
|
err = volOptions.ensureEncryptionMetadataSet(rbdImageEncrypted)
|
|
if err != nil {
|
|
return "", fmt.Errorf("failed to update encryption state for rbd image %s", imageSpec)
|
|
}
|
|
default:
|
|
return "", fmt.Errorf("can not encrypt rbdImage %s that already has file system: %s",
|
|
imageSpec, existingFormat)
|
|
}
|
|
} else if encrypted != rbdImageEncrypted {
|
|
return "", fmt.Errorf("rbd image %s found mounted with unexpected encryption status %s",
|
|
imageSpec, encrypted)
|
|
}
|
|
|
|
devicePath, err = openEncryptedDevice(ctx, volOptions, devicePath)
|
|
if err != nil {
|
|
return "", err
|
|
}
|
|
|
|
return devicePath, nil
|
|
}
|
|
|
|
func encryptDevice(ctx context.Context, rbdVol *rbdVolume, devicePath string) error {
|
|
passphrase, err := util.GetCryptoPassphrase(ctx, rbdVol.VolID, rbdVol.KMS)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to get crypto passphrase for %s: %v",
|
|
rbdVol, err)
|
|
return err
|
|
}
|
|
|
|
if err = util.EncryptVolume(ctx, devicePath, passphrase); err != nil {
|
|
err = fmt.Errorf("failed to encrypt volume %s: %v", rbdVol, err)
|
|
util.ErrorLog(ctx, err.Error())
|
|
return err
|
|
}
|
|
|
|
err = rbdVol.ensureEncryptionMetadataSet(rbdImageEncrypted)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, err.Error())
|
|
return err
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func openEncryptedDevice(ctx context.Context, volOptions *rbdVolume, devicePath string) (string, error) {
|
|
passphrase, err := util.GetCryptoPassphrase(ctx, volOptions.VolID, volOptions.KMS)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to get passphrase for encrypted device %s: %v",
|
|
volOptions, err)
|
|
return "", status.Error(codes.Internal, err.Error())
|
|
}
|
|
|
|
mapperFile, mapperFilePath := util.VolumeMapper(volOptions.VolID)
|
|
|
|
isOpen, err := util.IsDeviceOpen(ctx, mapperFilePath)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to check device %s encryption status: %s", devicePath, err)
|
|
return devicePath, err
|
|
}
|
|
if isOpen {
|
|
util.DebugLog(ctx, "encrypted device is already open at %s", mapperFilePath)
|
|
} else {
|
|
err = util.OpenEncryptedVolume(ctx, devicePath, mapperFile, passphrase)
|
|
if err != nil {
|
|
util.ErrorLog(ctx, "failed to open device %s: %v",
|
|
volOptions, err)
|
|
return devicePath, err
|
|
}
|
|
}
|
|
|
|
return mapperFilePath, nil
|
|
}
|
|
|
|
// xfsSupportsReflink checks if mkfs.xfs supports the "-m reflink=0|1"
|
|
// argument. In case it is supported, return true.
|
|
func (ns *NodeServer) xfsSupportsReflink() bool {
|
|
// return cached value, if set
|
|
if xfsHasReflink != xfsReflinkUnset {
|
|
return xfsHasReflink == xfsReflinkSupport
|
|
}
|
|
|
|
// run mkfs.xfs in the same namespace as formatting would be done in
|
|
// mountVolumeToStagePath()
|
|
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
|
|
out, err := diskMounter.Exec.Command("mkfs.xfs").CombinedOutput()
|
|
if err != nil {
|
|
// mkfs.xfs should fail with an error message (and help text)
|
|
if strings.Contains(string(out), "reflink=0|1") {
|
|
xfsHasReflink = xfsReflinkSupport
|
|
return true
|
|
}
|
|
}
|
|
|
|
xfsHasReflink = xfsReflinkNoSupport
|
|
return false
|
|
}
|