1
0
mirror of https://github.com/ceph/ceph-csi.git synced 2024-12-29 16:30:19 +00:00
ceph-csi/internal/liveness/liveness.go
Niels de Vos 6d00b39886 cleanup: move log functions to new internal/util/log package
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.

Updates: 
Signed-off-by: Niels de Vos <ndevos@redhat.com>
2021-08-26 09:34:05 +00:00

95 lines
2.6 KiB
Go

/*
Copyright 2019 The Ceph-CSI Authors.
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
*/
package liveness
import (
"context"
"time"
"github.com/ceph/ceph-csi/internal/util"
"github.com/ceph/ceph-csi/internal/util/log"
connlib "github.com/kubernetes-csi/csi-lib-utils/connection"
"github.com/kubernetes-csi/csi-lib-utils/metrics"
"github.com/kubernetes-csi/csi-lib-utils/rpc"
"github.com/prometheus/client_golang/prometheus"
"google.golang.org/grpc"
)
var liveness = prometheus.NewGauge(prometheus.GaugeOpts{
Namespace: "csi",
Name: "liveness",
Help: "Liveness Probe",
})
func getLiveness(timeout time.Duration, csiConn *grpc.ClientConn) {
ctx, cancel := context.WithTimeout(context.Background(), timeout)
defer cancel()
log.TraceLogMsg("Sending probe request to CSI driver")
ready, err := rpc.Probe(ctx, csiConn)
if err != nil {
liveness.Set(0)
log.ErrorLogMsg("health check failed: %v", err)
return
}
if !ready {
liveness.Set(0)
log.ErrorLogMsg("driver responded but is not ready")
return
}
liveness.Set(1)
log.ExtendedLogMsg("Health check succeeded")
}
func recordLiveness(endpoint, drivername string, pollTime, timeout time.Duration) {
liveMetricsManager := metrics.NewCSIMetricsManager(drivername)
// register prometheus metrics
err := prometheus.Register(liveness)
if err != nil {
log.FatalLogMsg(err.Error())
}
csiConn, err := connlib.Connect(endpoint, liveMetricsManager)
if err != nil {
// connlib should retry forever so a returned error should mean
// the grpc client is misconfigured rather than an error on the network
log.FatalLogMsg("failed to establish connection to CSI driver: %v", err)
}
// get liveness periodically
ticker := time.NewTicker(pollTime)
defer ticker.Stop()
for range ticker.C {
getLiveness(timeout, csiConn)
}
}
// Run starts liveness collection and prometheus endpoint.
func Run(conf *util.Config) {
log.ExtendedLogMsg("Liveness Running")
// start liveness collection
go recordLiveness(conf.Endpoint, conf.DriverName, conf.PollTime, conf.PoolTimeout)
// start up prometheus endpoint
util.StartMetricsServer(conf)
}