This commit makes modification so as to allow pvc-pvc clone
with different storageclass having different encryption
configs.
This commit also modifies `copyEncryptionConfig()` to
include a `isEncrypted()` check within the function.
Signed-off-by: Rakshith R <rar@redhat.com>
Example if a PVC was delete by setting `persistentVolumeReclaimPolicy` as
`Retain` on PV, and PV is reattached to a new PVC, we make sure to update
PV/PVC image metadata on a PV reattach.
Signed-off-by: Prasanna Kumar Kalever <prasanna.kalever@redhat.com>
Restoring a snapshot with a new PVC results with a wrong
dataPoolName in case of initial volume linked
to a storageClass with topology constraints and erasure coding.
Signed-off-by: Thibaut Blanchard <thibaut.blanchard@gmail.com>
Below are the 3 different cases where we need
the PVC namespace for encryption
* CreateVolume:- Read the namespace from the
createVolume parameters and store it in the omap
* NodeStage:- Read the namespace from the omap
not from the volumeContext
* Regenerate:- Read the pvc namespace from the claimRef
not from the volumeAttributes.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
This commit ensures that parent image is flattened before
creating volume.
- If the data source is a PVC, the underlying image's parent
is flattened(which would be a temp clone or snapshot).
hard & soft limit is reduced by 2 to account for depth that
will be added by temp & final clone.
- If the data source is a Snapshot, the underlying image is
itself flattened.
hard & soft limit is reduced by 1 to account for depth that
will be added by the clone which will be restored from the
snapshot.
Flattening step for resulting PVC image restored from snapshot is removed.
Flattening step for temp clone & final image is removed when pvc clone is
being created.
Fixes: #2190
Signed-off-by: Rakshith R <rar@redhat.com>
as we are moving the VolSize to rbdImage struct
we should reuse the same instead of maintaining
one more field in rbdSnapshot struct.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
we have added clusterID mapping to identify the volumes
in case of a failover in Disaster recovery in #1946.
with #2314 we are moving to a configuration in
configmap for clusterID and poolID mapping.
and with #2314 we have all the required information
to identify the image mappings.
This commit removes the workaround implementation done
in #1946.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
During PVC snapshot/clone both kms config and passphrase needs to copied,
while for PVC restore only passphrase needs to be copied to dest rbdvol
since destination storageclass may have another kms config.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit adds fetchMappedClusterIDAndMons() which returns
monitors and clusterID info after checking cluster mapping info.
This is required for regenerating omap entries in mirrored cluster
with different clusterID.
Signed-off-by: Rakshith R <rar@redhat.com>
Moving the log functions into its own internal/util/log package makes it
possible to split out the humongous internal/util packages in further
smaller pieces. This reduces the inter-dependencies between utility
functions and components, preventing circular dependencies which are not
allowed in Go.
Updates: #852
Signed-off-by: Niels de Vos <ndevos@redhat.com>
This commit adds functionality of extracting encryption kmsID,
owner from volumeAttributes in RegenerateJournal() and adds utility
functions ParseEncryptionOpts and FetchEncryptionKMSID.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit refractors RegenerateJournal() to take in
volumeAttributes map[string]string as argument so it
can extract required attributes internally.
Signed-off-by: Rakshith R <rar@redhat.com>
This commit fixes a bug in checkCloneImage() which was caused
by checking cloned image before checking on temp-clone image snap
in a subsequent request which lead to stale images. This was solved
by checking temp-clone image snap and flattening temp-clone if
needed.
This commit also fixes comparison bug in flattenCloneImage().
Signed-off-by: Rakshith R <rar@redhat.com>
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
nlreturn linter requires a new line before return
and branch statements except when the return is alone
inside a statement group (such as an if statement) to
increase code clarity. This commit addresses such issues.
Updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
We have many declarations and invocations..etc with long lines which are
very difficult to follow while doing code reading. This address the issues
in below files, and restrict the line length to 120 chars.
-internal/rbd/rbd_attach.go
-internal/rbd/rbd_journal.go
-internal/rbd/rbd_util.go
-internal/rbd/replicationcontrollerserver.go
-internal/rbd/snapshot.go
Signed-off-by: Humble Chirammal <hchiramm@redhat.com>
as we are supporting the creation of clone to a new
pool we need to pass the correct parent volume
to cleanup the snapshot on parent volume.
Co-authored-by: Madhu Rajanna <madhupr007@gmail.com>
Signed-off-by: Yug <yuggupta27@gmail.com>
This commit addresses ifshort linter issues which
checks if short syntax for if-statements is possible.
updates: #1586
Signed-off-by: Rakshith R <rar@redhat.com>
The rbdVolume that needs its encryption configured is constructed in the
Exists() method. It is suitable to move the copyEncryptionConfig() call
there as well, so that the object is completely constructed in a single
place.
Golang-ci:gocyclo complained about the increased complexity of the
Exists() function. Moving the repairing of the ImageID into its own
helper function makes the code a little easier to understand.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
In the case of the Async DR, the volumeID will
not be the same if the clusterID or the PoolID
is different, With Earlier implementation, it
is expected that the new volumeID mapping is
stored in the rados omap pool. In the case of the
ControllerExpand or the DeleteVolume Request,
the only volumeID will be sent it's not possible
to find the corresponding poolID in the new cluster.
With This Change, it works as below
The csi-rbdplugin-controller will watch for the PV
objects, when there are any PV objects created it
will check the omap already exists, If the omap doesn't
exist it will generate the new volumeID and it checks for
the volumeID mapping entry in the PV annotation, if the
mapping does not exist, it will add the new entry
to the PV annotation.
The cephcsi will check for the PV annotations if the
omap does not exist if the mapping exists in the PV
annotation, it will use the new volumeID for further
operations.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
There is no need for each EncryptionKMS to implement the same GetID()
function. We have a VolumeEncryption type that is more suitable for
keeping track of the KMS-ID that was used to get the configuration of
the KMS.
This does not change any metadata that is stored anywhere.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Because rbdVolume and rbdSnapshot are very similar, they can be based
off a common struct rbdImage that contains the common attributes and
functions.
This makes it possible to re-use functions for snapshots, and prevents
further duplication or code.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The rbdSnapshot and rbdVolume structs have many common attributes. In
order to combine these into an rbdImage struct that implements shared
functionality, having the same attribute for the ID makes things much
easier.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
Prepare for grouping encryption related functions together. The main
rbdVolume object should not be cluttered with KMS or DEK procedures.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
The Owner of an RBD image (Kubernetes Namespace, tenant) can be used to
identify additional configuration options. This will be used for
fetching the right Vault Token when encrypting/decrypting volumes.
Signed-off-by: Niels de Vos <ndevos@redhat.com>
If cephcsi encounters any error after
reservation, as a cleanup operation
it should revert back the reservation.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
If the omap data already exits return nil.
so that omap generator will not try to reserve
anything again.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
In the case of Disaster Recovery failover, the
user expected to create the static PVC's. We have
planned not to go with the PVC name and namespace
for many reasons (as in kubernetes it's planned to
support PVC transfer to a new namespace with a
different name and with new features coming in
like data populator etc). For now, we are
planning to go with static PVC's to support
async mirroring.
During Async mirroring only the RBD images are
mirrored to the secondary site, and when the
user creates the static PVC's on the failover
we need to regenerate the omap data. The
volumeHandler in PV spec is an encoded string
which contains clusterID and poolID and image UUID,
The clusterID and poolID won't remain same on both
the clusters, for that cephcsi need to generate the
new volume handler and its to create a mapping
between new volume handler and old volume handler
with that whenever cephcsi gets csi requests it
check if the mapping exists it will pull the new
volume handler and continues other operations.
The new controller watches for the PVs created,
It checks if the omap exists if it doesn't it
will regenerate the entire omap data.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
incase of async mirroring the volume UUID is
retrieved from the volume name, instead of cephcsi
generating a new UUID it should reserve the passed
UUID it will be useful when we support both metro DR
and async mirroring on a kubernetes clusters.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
Make sure to operate within the namespace if any given
when dealing with rbd images and snapshots and their journals.
Signed-off-by: Mehdy Khoshnoody <mehdy.khoshnoody@gmail.com>
This change replaces the sentinel errors in rbd module with
standard errors created with errors.New().
Related: #1203
Signed-off-by: Sven Anderson <sven@redhat.com>
Added support for RBD PVC to PVC cloning, below
commands are executed to create a PVC-PVC clone from
RBD side.
* Check the depth(n) of the cloned image if n>=(hard limit -2)
or ((soft limit-2) Add a task to flatten the image and return
about (to avoid image leak) **Note** will try to flatten the
temp clone image in the chain if available
* Reserve the key and values in omap (this will help us to
avoid the leak as it's not reserved earlier as we have returned
ABORT (the request may not come back))
* Create a snapshot of rbd image
* Clone the snapshot (temp clone)
* Delete the snapshot
* Snapshot the temp clone
* Clone the snapshot (final clone)
* Delete the snapshot
```bash
1) check the image depth of the parent image if flatten required
add a task to flatten image and return ABORT to avoid leak
(hardlimit-2 and softlimit-2 check will be done)
2) Reserve omap keys
2) rbd snap create <RBD image for src k8s volume>@<random snap name>
3) rbd clone --rbd-default-clone-format 2 --image-feature
layering,deep-flatten <RBD image for src k8s volume>@<random snap>
<RBD image for temporary snap image>
4) rbd snap rm <RBD image for src k8s volume>@<random snap name>
5) rbd snap create <cloned RBD image created in snapshot process>@<random snap name>
6) rbd clone --rbd-default-clone-format 2 --image-feature <k8s dst vol config>
<RBD image for temporary snap image>@<random snap name> <RBD image for k8s dst vol>
7)rbd snap rm <RBD image for src k8s volume>@<random snap name>
```
* Delete temporary clone image created as part of clone(delete if present)
* Delete rbd image
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>
during the checkSnapCloneExists we are checking
the image, if the image not found we are deleting
the snapshot on the parent image, This PR corrects
the comparasion. instead of snapshotNotFound we need
to check ImageNotFound error.
Signed-off-by: Madhu Rajanna <madhupr007@gmail.com>